Clinical application of a gantry-attachable plastic scintillating plate dosimetry system in pencil beam scanning proton therapy beam monitoring

Authors
Jeong, SeonghoonYoon, MyonggeunChung, KwangzooAhn, Sung HwanLee, BoramSeo, Jaehyeon
Issue Date
9월-2020
Publisher
ELSEVIER SCI LTD
Keywords
Pencil beam scanning proton therapy; Treatment beam verification; Plastic scintillating plate; Dose monitoring
Citation
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, v.77, pp.181 - 186
Indexed
SCIE
SCOPUS
Journal Title
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS
Volume
77
Start Page
181
End Page
186
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/53659
DOI
10.1016/j.ejmp.2020.08.019
ISSN
1120-1797
Abstract
Purpose: The entrance beam fluence of therapeutic proton scanning beams can be monitored using a gantry attachable plastic scintillating plate (GAPSP). This study evaluated the clinical application of the GAPSP using a method that measures intensity modulated proton therapy (IMPT) beams for patient treatment. Methods: IMPT beams for the treatment of nine patients, at sites that included the spine, head and neck, pelvis, and lung, were measured using the GAPSP, composed of an EJ-212 plastic scintillator and a CMOS camera. All energy layers distinguished by the GAPSP were accumulated to determine the dose distribution of the treatment field. The evaluated fields were compared with reference dose maps verified by quality assurance. Results: Comparison of dose distributions of evaluation treatment fields with reference dose distributions showed that the 3%/1 mm average gamma passing rate was 96.4%, independent of the treatment site, energy range and field size. When dose distributions were evaluated using the same criteria for each energy layer, the average gamma passing rate was 91.7%. Conclusions: The GAPSP is a suitable, low-cost method for monitoring pencil beam scanning proton therapy, especially for non-spot scanning or additional collimation. The GAPSP can also estimate the treatment beam by the energy layer, a feature not common to other proton dosimetry tools.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Myong geun photo

Yoon, Myong geun
보건과학대학 (바이오의공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE