Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Efficiency improvement of energy storage and release by the inlet position control for seasonal thermal energy storage

Authors
Lim, Hwan SukOk, JungSooPark, Jin SooLee, Seung JooKarng, Sarng WooKang, Yong Tae
Issue Date
4월-2020
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Coupled heat transfer; Efficiency improvement; Inlet position control; Seasonal energy storage; Temperature gradient; Thermal energy release
Citation
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, v.151
Indexed
SCIE
SCOPUS
Journal Title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Volume
151
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/56737
DOI
10.1016/j.ijheatmasstransfer.2020.119435
ISSN
0017-9310
Abstract
Borehole Thermal Energy Storage (BTES) system is considered one of the most practical technologies in the fields of new regeneration energy or energy conversion. The BTES system can store the solar energy in summer or the waste energy from power plant. It is important to store thermal energy in the BTES system before releasing the energy. Generally, the inlet position for heat source injection is fixed in the BTES system. In this study, the inlet position control method according to the temperature distribution between the borehole and the injected heat source is investigated during the thermal energy storage process. It is confirmed that the energy loss of the conventional type could be minimized and the thermal energy storage efficiency could be improved by controlling the inlet position. Also, the thermal energy release efficiency of the inlet control type is compared with that of the conventional type. The ANSYS/Fluent is used for the simulation analysis of the efficiency improvement by the inlet position control method. The coupled heat transfer calculation between fluid and solid is applied. In the BTES system with the radius of 12.5 m and the depth of 33.5 m, the storage efficiency and thermal energy sharing ratio are improved by 24.4% and 69.4% respectively at the end of the third year during the storage period. And the inlet control type could store the low-grade thermal heat source in the low temperature region of the BTES system, leading to the improvement of the release efficiency by the inlet position control. (C) 2020 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Yong Tae photo

Kang, Yong Tae
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE