Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Selective C2H2 detection with high sensitivity using SnO2 nanorod based gas sensors integrated with a gas chromatography

Authors
Lee, Jun HoPark, Min SunJung, HwaebongChoe, Yong-SahmKim, WonkyungSong, Young GeunKang, Chong-YunLee, Hyun-SookLee, Wooyoung
Issue Date
15-3월-2020
Publisher
ELSEVIER SCIENCE SA
Keywords
Acetylene gas sensor; SnO2 nanorod array; Metal catalyst; Miniaturized gas chromatography; Dissolved gas analysis; Transformer oil
Citation
SENSORS AND ACTUATORS B-CHEMICAL, v.307
Indexed
SCIE
SCOPUS
Journal Title
SENSORS AND ACTUATORS B-CHEMICAL
Volume
307
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/57274
DOI
10.1016/j.snb.2019.127598
ISSN
0925-4005
Abstract
We report on the sensitive and selective sensing properties of SnO2 nanorods (NRs) based gas sensors coupled with a miniature gas chromatography (mini-GC) system for the detection of acetylene. The SnO2 NRs were fabricated by a glancing angle deposition (GLAD) method and their average height and diameter were similar to 200 nm and similar to 30 nm, respectively. In order to overcome a selectivity issue of metal oxide semiconductor gas sensors, we integrated our SnO2 NRs based sensors with a packed column. The device accurately and selectively detected acetylene within 2 min (similar to 120 s). We found that loading a thin layer (5 nm) of metal catalysts such as Au, Pt or Pd increases the sensing abilities of the SnO2 NRs sensors. Among the tested sensors, the Pd-coated SnO2 NRs sensor (Pd-SnO2 NRs) exhibited the best sensing performance for the detection of 10 ppm of acetylene and the lower detection limit of 0.01 ppm. The superior sensing properties of Pd-SnO2 NRs are due to the large amount of oxygen deficiencies on the surface of Pd-SnO2 NRs, which acts as reactive sites. More importantly, the mini-GC device can be used to selectively detect 10 ppm of acetylene from other gases such as H-2. Our findings demonstrate that Pd-SnO2 NRs integrated with a mini-GC device can be utilized to monitor the dissolved acetylene gas in transformer oil in real time.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > KU-KIST Graduate School of Converging Science and Technology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE