Measurement of the Angle of Exodeviation With Polarized Glasses in Intermittent Exotropia

Authors
Ha, Suk-GyuKim, Seung-Hyun
Issue Date
3월-2020
Publisher
ELSEVIER SCIENCE INC
Citation
AMERICAN JOURNAL OF OPHTHALMOLOGY, v.211, pp.94 - 97
Indexed
SCIE
SCOPUS
Journal Title
AMERICAN JOURNAL OF OPHTHALMOLOGY
Volume
211
Start Page
94
End Page
97
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/57414
DOI
10.1016/j.ajo.2019.10.029
ISSN
0002-9394
Abstract
PURPOSE: The purpose of this study was to investigate if the angle of deviation with Polarized glasses is effective for measuring maximal angles in patients with intermittent exotropia (IXT). DESIGN: Prospective cross-sectional study. METHODS: This study was conducted on patients with > 10 prism diopters (PD) of basic -type IXT at distance and near. Three consecutive, different methods for measurement of the angle of deviation were used: alternate prism cover test (ACT), ACT with Polarized glasses (Polaroid test), and ACT after 1 hour of monocular occlusion (occlusion test). Comparison of the 3 methods of measurement was conducted using the Friedman repeated ANOVA and Wilcoxon signed rank test. RESULTS: A total of 60 patients were included in this study. Thirty (50%) patients were male. Mean age was 8.7 +/- 5.1 years (range, 4-37 years) and measurements by ACT at distance and near were 25.2 +/- 8.0 PD and 25.4 +/- 8.2 PD, respectively. Angles of Polaroid and occlusion tests (29.0 +/- 8.6 PD vs 30.6 +/- 8.1 PD) were significantly increased compared to that of ACT at distance (P<.01), and there was no significant change between angles of Polaroid and occlusion tests at distance (P=.06). However, there was no significant change between angles of ACT and Polaroid tests (25.4 +/- 8.2 PD vs 26.9 8.1 PD) at near (P=.07). CONCLUSION: The angle of deviation with Polarized glasses at distance increased and was comparable to that after the monocular occlusion test. The angle of exodeviation with Polarized glasses may be an easy, simple and effective alternative to measurement of maximum angle of deviation in IXT. ((C) 2019 Elsevier Inc. All rights reserved.)
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Seung Hyun photo

Kim, Seung Hyun
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE