Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Changes in the Matrix Metalloproteinase 9 Point-of-Care Test Positivity According to MMP-9 Concentration and Loading Volume

Authors
Huh, JungahChoi, Soo YounEom, YoungsubKim, Hyo MyungSong, Jong Suk
Issue Date
2월-2020
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Keywords
MMP-9; InflammaDry; point-of-care test; tear concentration
Citation
CORNEA, v.39, no.2, pp.234 - 236
Indexed
SCIE
SCOPUS
Journal Title
CORNEA
Volume
39
Number
2
Start Page
234
End Page
236
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/57772
DOI
10.1097/ICO.0000000000002096
ISSN
0277-3740
Abstract
Purpose: To measure changes in the matrix metalloproteinase 9 (MMP-9) point-of-care test, InflammaDry (Rapid Pathogen Screening, Inc, Sarasota, FL) positivity, based on ocular surface MMP-9 concentrations and loading volume. Methods: Two different MMP-9 products, preform and active, were analyzed using the InflammaDry test, detecting MMP-9 levels of more than 40 ng/mL of both preform and active MMP-9. Preform MMP-9 (Natural human MMP-9 protein; Abcam, Cambridge, UK) was analyzed at different concentrations (50, 100, 500, 1000, and 1500 ng/mL) and loading volumes (5, 10, and 20 mu L). Active MMP-9 (Human MMP-9 protein; Novus Biologicals, Littleton, CO) was also analyzed using the InflammaDry test at different concentrations (50 and 100 ng/mL) and loading volumes (10, 20, and 40 mu L). Results: Natural human MMP-9 protein (preform) of 50, 100, and 500 ng/mL exhibited negative results for every loading volume. At 1000 ng/mL, the 20 mu L volume was positive, whereas the 5 and 10 mu L volumes were negative. At 1500 ng/mL, all loading volumes were positive, but the density of positive bands varied depending on the loading volume; larger loading volumes had higher band density. Human MMP-9 protein (active) of 50 ng/mL was negative for every loading volume. In 100 ng/mL, the 20 and 40 mu L volumes showed positive results with similar positive band densities. Conclusions: The InflammaDry test had a different detection range depending on MMP-9 formulas; higher concentrations of preform MMP-9 protein were needed to yield positive results. In addition, InflammaDry positivity varied based on the loading volumes. Clinicians should be aware of the possibility of false negatives with low tear volumes despite elevated MMP-9 concentrations.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE