Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Sterilization efficiency of pathogen-contaminated cottons in a laundry machine

Authors
Shin, YoonjaePark, JunghaPark, Woojun
Issue Date
1월-2020
Publisher
MICROBIOLOGICAL SOCIETY KOREA
Keywords
Acinetobacter baumannii; desiccation tolerance; dry conditions; drying machine; Staphylococcus aureus; washing machine
Citation
JOURNAL OF MICROBIOLOGY, v.58, no.1, pp.30 - 38
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF MICROBIOLOGY
Volume
58
Number
1
Start Page
30
End Page
38
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/58471
DOI
10.1007/s12275-020-9391-1
ISSN
1225-8873
Abstract
Pathogenic bacteria on abiotic surfaces such as fabrics, bedding, patient wears, and surgical tools are known to increase the risk of bacterial diseases in infants and the elderly. The desiccation tolerance of bacteria affects their viability in cotton. Thus, washing and drying machines are required to use conditions that ensure the sterilization of bacteria in cotton. The objective of this study is to determine the effects of various sterilization conditions of washing and drying machines on the survival of three pathogenic bacteria (Acinetobacter baumannii, Pseudomonas aeruginosa, and Staphylococcus aureus) commonly presented in contaminated cotton and two non-pathogenic bacteria (Bacillus subtilis and Escherichia coli) in cotton. High survival rates of A. baumannii and S. aureus in desiccated cotton were observed based on scanning electron microscope and replicate organism direct agar contact assay. The survival rates of A. baumannii and S. aureus exposed in desiccated cotton for 8 h were higher (14.4 and 5.0%, respectively) than those of other bacteria (< 0.5%). All tested bacteria were eradicated at low-temperature (< 40 degrees C) washing with activated oxygen bleach (AOB). However, bacterial viability was shown in low temperature washing without AOB. High-temperature (> 60 degrees C) washing was required to achieve 99.9% of the sterilization rate in washing without AOB. The sterilization rate was 93.2% using a drying machine at 60 degrees C for 4 h. This level of sterilization was insufficient in terms of time and energy efficiency. High sterilization efficiency (> 99.9%) at 75 degrees C for 3 h using a drying machine was confirmed. This study suggests standard conditions of drying machines to remove bacterial contamination in cotton by providing practical data.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Sciences and Biotechnology > Division of Environmental Science and Ecological Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Woo jun photo

Park, Woo jun
생명과학대학 (환경생태공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE