Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Collimators for Gamma Dual Energy CT Arch-Detector: A Simulation Study

Authors
Pratiwi, EvaBae, SeungbinLee, HakjeeUllah, Muhammad NasirLee, BoramLee, KisungYeom, Jungyeol
Issue Date
1월-2020
Publisher
KOREAN PHYSICAL SOC
Keywords
Dual energy; CT; Material detection; Arch detector
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.76, no.1, pp.79 - 85
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
76
Number
1
Start Page
79
End Page
85
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/58506
DOI
10.3938/jkps.76.79
ISSN
0374-4884
Abstract
The image resolution of computed tomography (CT) scan system can be affected by numbers of factors such as collimator material, collimator design, stopping power of detector and scatter photons rejection and/or correction technique. The scatter photons are one of the major sources of background noise that can immensely degrade the image quality of the CT system. The image quality, in turn, affects the discrimination and identification performance of the system especially in the case of dual-energy CT systems for material decomposition. Therefore, for material identification, acquisition of raw data with minimal noise is of immense importance. In this simulation study, the performance of two types of collimators was evaluated to come up with a better collimator design for background noise compression. Both collimators were made of tungsten with similar length of 30 mm but with different hole shapes (fan and parallel). In both cases, results suggest that there is a clear improvement in terms of spatial resolution. In a comparison of grids structure, fan grid performed slightly better than parallel for most of the cases. The peak-to-valley (PV) ratio for 122 keV gamma radiation source improved on average similar to 0.16 (16%) and similar to 0.23 (23%) for fan collimator and parallel collimator respectively. For 60 keV gamma source, the improvements were similar to 0.14 (14%) and similar to 0.17 (17%) respectively. Thus, from the results, it can be concluded that fan grid collimator can provide superior performance compared to parallel grid collimator.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Ki sung photo

Lee, Ki sung
바이오의공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE