Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance comparison of platelet function analyzers in cardiology patients: VerifyNow and Anysis-200 aspirin assays

Authors
Chung, Young HakLee, Kyung AhCho, MinheeShin, SehyunLee, Byoung Kwon
Issue Date
2020
Publisher
IOS PRESS
Keywords
Platelet function; aspirin; Anysis-200 analyzer; VerifyNow
Citation
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, v.76, no.1, pp.33 - 42
Indexed
SCIE
SCOPUS
Journal Title
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION
Volume
76
Number
1
Start Page
33
End Page
42
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/59044
DOI
10.3233/CH-200822
ISSN
1386-0291
Abstract
BACKGROUND: Analysis of responsiveness to antiplatelet therapy is crucial in the management of patients with cardiovascular diseases. OBJECTIVE: This study aimed to evaluate a new platelet function analysis system (Anysis-200) and to compare it with VerifyNow (Accumetrics, San Diego, CA, USA) in cardiology patients. METHODS: Overall, 125 citrated blood samples were collected from 85 cardiology patients referred for platelet function testing. In Anysis-200, platelet function was measured as blood migration distance (MD) until clogging of flow passage, which is comparable to aspirin resistance units obtained using VerifyNow. The two devices were simultaneously used and compared. RESULTS: The MDs before and after taking aspirin were 175 +/- 51 and 247 +/- 27 mm, respectively (p < 0.0001). Compared with VerifyNow (reference), the sensitivity and specificity of Anysis-200 was 91.5% and 75.5%, respectively (area under the curve, 0.829). Further, the true positive rate in patients newly taking aspirin was 85% for VerifyNow and 92.5% for Anysis-200, respectively. The Cohen's kappa coefficient between the two devices was 0.682, indicating a relatively high agreement. CONCLUSIONS: Anysis-200, a novel system for assessing platelet aggregation, has accuracy and precision equivalent to that of, and significant agreement with, VerifyNow. Anysis-200 may be useful in screening patients with abnormal platelet reactivity and aspirin nonresponsiveness.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Se hyun photo

Shin, Se hyun
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE