Development of a Virtual Frisch-Grid CZT Detector Based on the Array StructureDevelopment of a Virtual Frisch-Grid CZT Detector Based on the Array Structure

Other Titles
Development of a Virtual Frisch-Grid CZT Detector Based on the Array Structure
Authors
김영학이원호
Issue Date
2020
Publisher
대한방사선방어학회
Keywords
Virtual Frisch-Grid CZT; Array Structure; Spectroscopy; Compton Imaging; Radiation Monitoring
Citation
방사선방어학회지, v.45, no.1, pp.35 - 44
Indexed
SCOPUS
KCI
Journal Title
방사선방어학회지
Volume
45
Number
1
Start Page
35
End Page
44
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/59775
ISSN
2508-1888
Abstract
Background: Cadmium zinc telluride (CZT) is a promising material because of a high detection efficiency, good energy resolution, and operability at room temperature. However, the cost of CZT dramatically increases as its size increases. In this study, to achieve a large effective volume with relatively low cost, an array structure comprised of individual virtual Frisch-grid CZT detectors was proposed. Materials and Methods: The prototype consisted of 2 × 2 CZTs, a holder, anode and cathode printed circuit boards (PCBs), and an application-specific integrated circuit (ASIC). CZTs were used and the non-contacting shielding electrode method was applied for virtual Frisch-grid effect. An ASIC was used, and the holder and the PCBs were fabricated. In the current system, because the CZTs formed a common cathode, a total of 5 channels were assigned for data processing. Results and Discussion: An experiment using 137Cs at room temperature was conducted for 10 minutes. Energy and timing information was acquired and the depth of interaction was calculated by the timing difference between the signals of both electrodes. Based on obtained three-dimensional position information, the energy correction was carried out, and as a result the energy spectra showed the improvements. In addition, a Compton image was reconstructed using the iterative method. Conclusion: The virtual Frisch-grid CZT detector based on the array structure was developed and the energy spectra and the Compton image were successfully acquired.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Won ho photo

Lee, Won ho
보건과학대학 (보건환경융합과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE