Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Modeling and Simulation Performance Evaluation of a Proposed Calorimeter for Testing a Heat Pump System

Authors
Amoabeng, Kofi OwuraLee, Kwang HoChoi, Jong Min
Issue Date
1-12월-2019
Publisher
MDPI
Keywords
air handling unit; calorimeter; energy consumption; heat pump; heat recovery unit; test chamber
Citation
ENERGIES, v.12, no.23
Indexed
SCIE
SCOPUS
Journal Title
ENERGIES
Volume
12
Number
23
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/60984
DOI
10.3390/en12234589
ISSN
1996-1073
Abstract
The energy consumption for heating and cooling in the building sector accounts for more than one-third of total energy used worldwide. In view of that, it is important to develop energy efficient cooling and heating systems in order to conserve energy in buildings as well as reduce greenhouse gas emissions. In both commercial and residential buildings, the heat pump has been adopted as an energy efficient technology for space heating and cooling purposes as compared to conventional air conditioning systems. However, heat pumps undergo standard testing, rating, and certification procedures to ascertain their system performance. Essentially, the calorimeter for testing heat pumps has two test chambers to serve as a heat source and heat sink to control and maintain the test conditions required to simulate the heat pump indoor and outdoor units, simultaneously. In air-to-air heat pump units, the conventional calorimeter controls the air temperature and humidity conditions in each test chamber with separate air handling units consisting of a refrigerator, heater, humidifier, and supply fan, which results in high energy consumption. In this study, using dynamic modeling and simulation, a new calorimeter for controlling air conditions in each test chamber is proposed. The performance analysis based on simulation results showed that the newly proposed calorimeter predicted at least 43% energy savings with the use of a heat recovery unit and small refrigerator capacity as compared to the conventional calorimeter that utilized a large refrigerator capacity for all the weather conditions and load capacities that we investigated.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Architecture > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE