Stability of bioresorbable plates following reduction of mandibular body fracture: Three-dimensional analysis

Authors
Song, In-SeokChoi, JimiKim, Seong RyoungLee, Jee-Ho
Issue Date
Nov-2019
Publisher
CHURCHILL LIVINGSTONE
Keywords
Three-dimensional coordinate system; Bioresorbable plate; Mandibular body fracture
Citation
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, v.47, no.11, pp.1752 - 1757
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY
Volume
47
Number
11
Start Page
1752
End Page
1757
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/62026
DOI
10.1016/j.jcms.2019.07.033
ISSN
1010-5182
Abstract
Purpose: The recent development of bioresorbable bone plates and screws allows plates to be applied to the load-bearing regions of the mandible and to remain in place over time without the need for removal. We hypothesized that the stability of composite plates and screws forged from unsintered hydroxyapatite particles and poly-L-lactide (u-HA/PLLA) is comparable to that of standard titanium fixation systems for the reduction of fractures of load-bearing regions of the mandibular body. Materials and methods: 40 patients underwent open reduction and internal fixation of the fractured mandibular body with either a titanium or u-HA/PLLA bone plate. Cone-beam CT images were obtained immediately postoperatively and at 6-month follow-up, and were analyzed for positional changes of the affected mandible. Results: There were no significant differences in the postoperative positional changes of reference points between the titanium and u-HA/PLLA miniplates, except for that for the coronoid process (pvalue = 0.03). Multivariate regression analysis revealed no significant differences in spatial changes between the immediate postoperative and 6-month follow-up images, after adjusting for age and sex. Conclusion: The stability of bioresorbable u-HA/PLLA miniplates and screws was comparable to that of titanium miniplates and screws immediately postoperatively and at 6-month follow-up, following surgical reduction of fractures of load-bearing regions of the mandibular body. Bioresorbable osteosynthesis can be considered a viable alternative to titanium osteosynthesis. 2019 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE