High voltage calibration method for the CMS RPC detector
- Authors
- Reyes-Almanza, R.; Dimitrov, A.; Fagot, A.; Gul, M.; Roskas, C.; Tytgat, M.; Zaganidis, N.; Fonseca De Souza, S.; Santoro, A.; Da Silva De Araujo, F. Torres; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Rodozov, M.; Shopova, M.; Sultanov, G.; Litov, L.; Pavlov, B.; Petkov, P.; Petrov, A.; Qian, S. J.; Han, D.; Yi, W.; Avila, C.; Cabrera, A.; Carrillo, C.; Segura, M.; Aly, S.; Assran, Y.; Mahrous, A.; Mohamed, A.; Combaret, C.; Gouzevitch, M.; Grenier, G.; Lagarde, F.; Laktineh, I. B.; Mathez, H.; Mirabito, L.; Shchablo, K.; Bagaturia, I.; Lomidze, D.; Lomidze, I.; Pant, L. M.; Bhatnagar, V.; Gupta, R.; Kumari, R.; Lohan, M.; Singh, J. B.; Amoozegar, V.; Boghrati, B.; Ghasemy, H.; Malmir, S.; Najafabadi, M. Mohammadi; Abbrescia, M.; Gelmi, A.; Iaselli, G.; Lezki, S.; Pugliese, G.; Benussi, L.; Bianco, S.; Piccolo, D.; Primavera, F.; Buontempo, S.; Crescenzo, A.; Galati, G.; Fienga, F.; Orso, I.; Lista, L.; Meola, S.; Paolucci, P.; Voevodina, E.; Braghieri, A.; Montagna, P.; Ressegotti, M.; Riccardi, C.; Salvini, P.; Vitulo, P.; Cho, S. W.; Choi, S. Y.; Hong, B.; Lee, K. S.; Lim, J. H.; Park, S. K.; Goh, J.; Kim, T. J.; Carrillo Moreno, S.; Miguel Colin, O.; Vazquez Valencia, F.; Carpinteyro Bernardino, S.; Eysermans, J.; Pedraza, I.; Uribe Estrada, C.; Duran-Osuna, M. C.; Ramirez-Garcia, M.; Ramirez-Sanchez, G.; Sanchez-Hernandez, A.; Rabadan-Trejo, R. I.; Castilla-Valdez, H.; Radi, A.; Hoorani, H.; Muhammad, S.; Shah, M. A.; Crotty, I.
- Issue Date
- 9월-2019
- Publisher
- IOP PUBLISHING LTD
- Keywords
- Detector alignment and calibration methods (lasers, sources, particle-beams); Performance of High Energy Physics Detectors; Resistive-plate chambers
- Citation
- JOURNAL OF INSTRUMENTATION, v.14, no.9
- Indexed
- SCIE
SCOPUS
- Journal Title
- JOURNAL OF INSTRUMENTATION
- Volume
- 14
- Number
- 9
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/63451
- DOI
- 10.1088/1748-0221/14/09/C09046
- ISSN
- 1748-0221
- Abstract
- The Resistive Plate Chambers (RPC) are used for muon triggers in the CMS experiment. To calibrate the high voltage working-points (WP) and identify degraded detectors due to radiation or chemical damage, a high voltage scan has been performed using 2017 data from pp collisions at a center-of-mass energy of 13 TeV. In this paper, we present the calibration method and the latest results obtained for the 2017 data. A comparison with all scans taken since 2011 is considered to investigate the stability of the detector performance in time.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Science > Department of Physics > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.