Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Improvement in Recovery of Hemodynamic Responses by Extended Kalman Filter With Non-Linear State-Space Model and Short Separation Measurement

Authors
Dong, SungheeJeong, Jichai
Issue Date
8월-2019
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Functional near-infrared spectroscopy; noise reduction; extended Kalman filter; non-linear state-space model; short separation measurement
Citation
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, v.66, no.8, pp.2152 - 2162
Indexed
SCIE
SCOPUS
Journal Title
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume
66
Number
8
Start Page
2152
End Page
2162
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/63681
DOI
10.1109/TBME.2018.2884169
ISSN
0018-9294
Abstract
Objective: The purpose of this study is to describe the noise reduction in the hemodynamic responses, obtained by functional near-infrared spectroscopy (fNIRS), using the proposed extended Kalman filter (EKF) with a non-linear state-space model, aided by the short separation (SS) measurement. Methods: The authors used the simulated data by adding the synthetic hemodynamic response function (HRF) to the multi-distance four-channel fNIRS signals obtained during the resting state. EKF was used to estimate the non-linear state-space model designed based on the Balloon model. The SS channel was used as a regressor that is sensitive only to superficial noises. The whole segments were grouped by the existence of motion artifacts (MAs) to investigate the improvement by EKF compared to the linear Kalman filter (LKF) and adaptive filter (AF) in extracting neural-evoked hemodynamic. Results: Kalman-based approaches were better than AF in reducing noises. Using EKF, the averages of the decreased errors and increased correlation between the recovered and true HRF were 34% in oxy-hemoglobin and 62% in deoxy-hemoglobin concentrations in segments having MAs, compared with LKF. In the MA-free condition, EKF is more robust to the poor quality of signals in noise reduction than LKF. Conclusion: The proposed non-linear Kalman approach is better in noise reduction than AF and LKF especially in noisy deoxy-hemoglobin concentrations, and less affected by the conditions of measurements and contaminations by MAs. Significance: The proposed method can be used for reducing superficial noises and MAs from fNIRS signals as an upgraded alternative to existing AFs.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Brain and Cognitive Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE