Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A chemiluminescence resonance energy transfer strategy and its application for detection of platinum ions and cisplatin

Authors
Cai, ShengZhou, YingYe, JiaweiChen, RuizheSun, LianliLu, JianzhongJung, CheulheeZeng, Su
Issue Date
7월-2019
Publisher
SPRINGER WIEN
Keywords
CRET; Streptavidin aptamer; Platinum-oligonucleotide coordination; Platinum aptameric platform; Platinum detection
Citation
MICROCHIMICA ACTA, v.186, no.7
Indexed
SCIE
SCOPUS
Journal Title
MICROCHIMICA ACTA
Volume
186
Number
7
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/64239
DOI
10.1007/s00604-019-3509-3
ISSN
0026-3672
Abstract
A novel chemiluminescence resonance energy transfer (CRET) system was developed and combined with a structure-switching aptamer for the highly sensitive detection of platinum. Platinum was chosen as a model analyte to demonstrate the generality of the new CRET system. This aptameric platform consisted of a streptavidin labeled aptamer against platinum and a streptavidin-coated magnetic bead for the selective separation of platinum-bound aptamer. The platinum-aptamer probe contained several guanine (G) bases bound to the 3,4,5-trimethoxyphenyl-glyoxal (TMPG) donor group at the 5 end, a fluorescent acceptor (6-carboxy-2,4,7,7-tetrachlorofluorescein, TET) at the 3 end, and a streptavidin aptamer sequence in which several base pairs were replaced by the G-G mismatch to induce the platinum-oligonucleotide coordination. The chemiluminescence (CL) generated by TMPG/G bases is transferred to the acceptor (TET). In the presence of platinum, the platinum-aptamer probe was folded such that the G bases at the 5 end and TET at the 3 were in close proximity. The complex was separated using streptavidin-coated magnetic beads by the addition of TMPG to form the TMPG/G bases complex. The ultraweak CL from the TMPG/G bases was strongly enhanced by TET. This novel CRET-based method can be easily performed with high limit of detection (50ngmL(-1)) and selectivity over other metal ions. This technique provides a novel method for simple, fast, and convenient point-of-care diagnostics for monitoring proteins and metal ions.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biotechnology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE