Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Deep-Learning-Based Multi-Modal Fusion for Fast MR Reconstruction

Authors
Xiang, LeiChen, YongChang, WeitangZhan, YiqiangLin, WeiliWang, QianShen, Dinggang
Issue Date
7월-2019
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Deep learning; dense block; fast MR reconstruction; multi-model fusion
Citation
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, v.66, no.7, pp.2105 - 2114
Indexed
SCIE
SCOPUS
Journal Title
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume
66
Number
7
Start Page
2105
End Page
2114
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/64244
DOI
10.1109/TBME.2018.2883958
ISSN
0018-9294
Abstract
T1-weighted image (T1WI) and T2-weighted image (T2WI) are the two routinely acquired magnetic resonance (MR) modalities that can provide complementary information for clinical and research usages. However, the relatively long acquisition time makes the acquired image vulnerable to motion artifacts. To speed up the imaging process, various algorithms have been proposed to reconstruct high-quality images from under-sampled k-space data. However, most of the existing algorithms only rely on mono-modality acquisition for the image reconstruction. In this paper, we propose to combine complementary MR acquisitions (i.e., T1WI and under-sampled T2WI particularly) to reconstruct the high-quality image (i.e., corresponding to the fully sampled T2WI). To the best of our knowledge, this is the first work to fuse multi-modal MR acquisitions through deep learning to speed up the reconstruction of a certain target image. Specifically, we present a novel deep learning approach, namely Dense-Unet, to accomplish the reconstruction task. The proposed Dense-Unet requires fewer parameters and less computation, while achieving promising performance. Our results have shown that Dense-Unet can reconstruct a three-dimensional T2WI volume in less than 10 s with an under-sampling rate of 8 for the k-space and negligible aliasing artifacts or signal-noise-ratio loss. Experiments also demonstrate excellent transferring capability of Dense-Unet when applied to the datasets acquired by different MR scanners. The above-mentioned results imply great potential of our method in many clinical scenarios.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Artificial Intelligence > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE