Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Smartphone compatible on-site fluorescence analyzer for spilled crude oil based on CMOS image sensor

Authors
Seo, DongminOh, SangwooShin, SanghoonLee, MoonjinHwang, YonghaSeo, Sungkyu
Issue Date
15-6월-2019
Publisher
ELSEVIER SCIENCE SA
Keywords
Complementary metal oxide semiconductor image sensors; Light-emitting diode; Crude oil detector; Fluorescence detector; Spilled oil analyzer; Point of testing
Citation
SENSORS AND ACTUATORS B-CHEMICAL, v.289, pp.93 - 99
Indexed
SCIE
SCOPUS
Journal Title
SENSORS AND ACTUATORS B-CHEMICAL
Volume
289
Start Page
93
End Page
99
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/64758
DOI
10.1016/j.snb.2019.03.086
ISSN
0925-4005
Abstract
Oil spills, both in the ocean and inland waters, have negative effects such as mass mortality and habitat destruction. In this study, we develop a spilled oil point-of-testing device (SOPD), a field measurement system for immediate on-site fluorescence monitoring of oil concentrations. Photodetectors, such as photodiodes and photo multiplier tubes, which are commonly used in existing instrumentation, have inherent limitations because they are capable of only single-pixel detection. However, SOPD can cope with environmental noise caused by dust, dirt, and impurities, by adopting a multi-mega pixel complementary metal-oxide semiconductor image sensor as a detector. Furthermore, the manufacturing cost is remarkably reduced by a simple optical configuration using only two light-emitting diode light sources, five optical lenses, and a CMOS sensor. SOPD can quantitatively analyze fluorescence intensities at both low (0-1 ppm) and high (1-800 ppm) concentrations in marine and inland environments, respectively. The performance of the equipment reported in this paper was demonstrated by measuring the linear measurement range and the limit of detection using five different kinds of crude oil. A correlation analysis of crude oil samples having different collection dates was also completed. In addition, SOPD has been developed as a remote system that can be operated and analyzed on a smartphone, thereby enhancing user convenience, reducing analysis time, and simplifying device.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Control and Instrumentation Engineering > 1. Journal Articles
Graduate School > Department of Electronics and Information Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seo, Sung kyu photo

Seo, Sung kyu
전자·정보공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE