Evaluation of Diffusion Lesion Volume Measurements in Acute Ischemic Stroke Using Encoder-Decoder Convolutional Network
- Authors
- Kim, Yoon-Chul; Lee, Ji-Eun; Yu, Inwu; Song, Ha-Na; Baek, In-Young; Seong, Joon-Kyung; Jeong, Han-Gil; Kim, Beom Joon; Nam, Hyo Suk; Chung, Jong-Won; Bang, Oh Young; Kim, Gyeong-Moon; Seo, Woo-Keun
- Issue Date
- 6월-2019
- Publisher
- LIPPINCOTT WILLIAMS & WILKINS
- Keywords
- cerebral infarction; deep learning; diffusion; ischemia; neurologist
- Citation
- STROKE, v.50, no.6, pp.1444 - 1451
- Indexed
- SCIE
SCOPUS
- Journal Title
- STROKE
- Volume
- 50
- Number
- 6
- Start Page
- 1444
- End Page
- 1451
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/65337
- DOI
- 10.1161/STROKEAHA.118.024261
- ISSN
- 0039-2499
- Abstract
- Background and Purpose Automatic segmentation of cerebral infarction on diffusion-weighted imaging (DWI) is typically performed based on a fixed apparent diffusion coefficient (ADC) threshold. Fixed ADC threshold methods may not be accurate because ADC values vary over time after stroke onset. Deep learning has the potential to improve the accuracy, provided that a large set of correctly annotated lesion data is used for training. The purpose of this study was to evaluate deep learning-based methods and compare them with commercial software in terms of lesion volume measurements. Methods U-net, an encoder-decoder convolutional neural network, was adopted to train segmentation models. Two U-net models were developed: a U-net (DWI+ADC) model, trained on DWI and ADC data, and a U-net (DWI) model, trained on DWI data only. A total of 296 subjects were used for training and 134 for external validation. An expert neurologist manually delineated the stroke lesions on DWI images, which were used as the ground-truth reference. Lesion volume measurements from the U-net methods were compared against the expert's manual segmentation and Rapid Processing of Perfusion and Diffusion (RAPID; iSchemaView Inc) analysis. Results In external validation, U-net (DWI+ADC) showed the highest intraclass correlation coefficient with manual segmentation (intraclass correlation coefficient, 1.0; 95% CI, 0.99-1.00) and sufficiently high correlation with the RAPID results (intraclass correlation coefficient, 0.99; 95% CI, 0.98-0.99). U-net (DWI+ADC) and manual segmentation resulted in the smallest 95% Bland-Altman limits of agreement (-5.31 to 4.93 mL) with a mean difference of -0.19 mL. Conclusions The presented deep learning-based method is fully automatic and shows a high correlation of diffusion lesion volume measurements with manual segmentation and commercial software. The method has the potential to be used in patient selection for endovascular reperfusion therapy in the late time window of acute stroke.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - Graduate School > Department of Artificial Intelligence > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.