Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Radiological morphometric analysis of the zygomatic arch: Application of osteosynthesis on the upper arch border for rigid fixation

Authors
Kim, HyonsurkYoon, JeongminLee, Byung-il
Issue Date
5월-2019
Publisher
ELSEVIER SCI LTD
Keywords
Zygomatic arch fracture; Zygomatic arch morphometry; Zygomatic arch fracture open reduction and internal fixation; Zygomatic arch tangential fixation
Citation
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, v.72, no.5, pp.831 - 841
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY
Volume
72
Number
5
Start Page
831
End Page
841
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/65860
DOI
10.1016/j.bjps.2018.11.014
ISSN
1748-6815
Abstract
Background: This study was designed to introduce a novel method of applying osteosynthetic materials to the upper zygomatic arch border for fracture fixation through a temporal incision, and analyze the radiologic morphometric dimensions of the arch to verify its validity. Methods: Radiological morphometry was analyzed in 51 adult patients with unilateral isolated zygomatic arch fractures. Frequent fracture sites, sites of minimal thickness and height, and their correlation were evaluated, as were the locations and dimensions of fixation vantage points. The novel surgical method based on the results was implemented in 17 clinical cases. Results: Frequent fracture sites, occurring 4.40, 16.47 and 30.48 mm posterior to the arch origin, did not correlate to sites of minimal height and thickness. Arch minimal thickness and height locations were 12.23 and 27.09 mm behind its origin, respectively. Fixation vantage point dimensions varied from point to point, with upper thickness ranging from 1.67 to 4.86 mm and mid-portion thickness ranging from 2.06 to 7.36 mm, and height ranging from 8.99 to 22.53 mm. Arch vertical axis inclination ranged from 6.51 degrees to 16.47 degrees, which increased as the arch stretches posteriorly. These results suggested the use of 1.5 mm-wide plates and 1 mmdiameter screws with 6-8 mm length. Patients received surgery based on these morphometry results for satisfactory stabilization. Conclusions: This study introduces a new method for open reduction and internal fixation of arch fractures, with morphometric analysis of the arch verifying the validity of tangential plate application to the upper border. (C) 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.