Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Greenhouse gas emission offsetting by refrigerant recovery from WEEE: A case study on a WEEE recycling plant in Korea

Authors
Park, JihwanJung, InsangChoi, WonheeChoi, Sang OkHan, Sung Won
Issue Date
3월-2019
Publisher
ELSEVIER SCIENCE BV
Keywords
Waste electrical and electronic equipment; Greenhouse gas; CO2 emissions; Carbon footprint; Offsetting; Recycling plant
Citation
RESOURCES CONSERVATION AND RECYCLING, v.142, pp.167 - 176
Indexed
SCIE
SCOPUS
Journal Title
RESOURCES CONSERVATION AND RECYCLING
Volume
142
Start Page
167
End Page
176
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/67170
DOI
10.1016/j.resconrec.2018.12.003
ISSN
0921-3449
Abstract
The demand for new electrical and electronic equipment (EEE) has resulted in short replacement cycles for this equipment. This has led to the generation of a large amount of waste electrical and electronic equipment (WEEE). The proper disposal of WEEE is essential in order to manage greenhouse gas (GHG) emissions, as refrigerant injected EEE is a potential source of GHG emissions. In this study, carbon dioxide (CO2) emissions from recycling activities that resulted in GHG emissions via refrigerant recovery were quantitatively evaluated. The evaluation was conducted based on the operational data from a WEEE recycling plant in 2016. To estimate CO2 emission and offsetting effects, mass-balance and carbon-footprint analyses were conducted. The mass balance data showed that 22,804 t of WEEE were recycled in a plant. The carbon-footprint analysis estimated that CO2 emissions from all recycling activities, including all machinery and vehicles as well as fossil fuel and electricity use, reached approximately 4.097 x 10(3) tonne of CO2 eq. Meanwhile, the CO2 emissions prevented by the manual recovery of refrigerants (5186 kg) from WEEE accounted for approximately 2.877 x 10(4) tonne of CO2 eq. These results, based on data from a recycling plant and showing an offset of CO2 emissions by a factor of 7.02, demonstrate that refrigerant recovery could potentially reduce emissions by 2.467 x 10(4) tonne of CO2 eq. per year. This study will demonstrate the optimal methodologies for estimating CO2 emissions and offsetting, and inform environmental policy by providing an alternative approach to the problem of global warming.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Political Science & Economics > Department of Public Administration > 1. Journal Articles
College of Engineering > School of Industrial and Management Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sung Won photo

Han, Sung Won
공과대학 (산업경영공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE