Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Accuracy of Dental Replica Models Using Photopolymer Materials in Additive Manufacturing: In Vitro Three-Dimensional Evaluation

Authors
Jin, Su-JinKim, Dong-YeonKim, Ji-HwanKim, Woong-Chul
Issue Date
2월-2019
Publisher
WILEY
Keywords
Additive manufacturing; dental replica model; photopolymer; precision; trueness
Citation
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, v.28, no.2, pp.E557 - E562
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY
Volume
28
Number
2
Start Page
E557
End Page
E562
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/67728
DOI
10.1111/jopr.12928
ISSN
1059-941X
Abstract
Purpose To evaluate the accuracy (trueness and precision) of dental replica models produced by using photopolymer materials in additive manufacturing. Materials and Methods A complete arch model was scanned using an extraoral scanner (Identica Blue) and established as reference. For the control group, 10 stone models were acquired through the conventional method from the reference model. For the experimental groups, digital data were acquired using an intraoral scanner (CEREC Omnicam), and 10 stereolithographic apparatus (SLA) models and 10 PolyJet models were made. All models were scanned with an extraoral scanner. Three-dimensional analysis software was used to measure differences between the 3D scanned images in root mean square values. The ISO-5725-1 specification was followed to measure trueness and precision between two 3D scanned data. Trueness was calculated by overlapping scanned data with the reference model and precision by performing pairwise intragroup comparisons. Also the ratio of region out of tolerance (> +/- 50 mu m) was measured. One-way ANOVA and Tukey's post hoc analysis were applied. Results There was no statistically significant difference in trueness between the stone and the SLA models (p > 0.05). Dental replica models using photopolymer materials showed statistically significantly better precision than that of the stone model (p 0.05). Regarding tolerance, no statistically significant difference was observed between the stone and the SLA models (p > 0.05). Conclusions Although the dental replica models using photopolymer materials did not show better trueness than the conventional stone models, there was no significant difference between the SLA and the stone models. Concerning precision, dental replica models using photopolymer materials presented better results than that of the conventional stone models. In sum, dental replica models using photopolymer materials showed sufficient accuracy for clinical use.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE