Filtration Performance Characteristics of Sticky Aerosol Using Calcium Hydroxide
- Authors
- Lee, Jae-Rang; Hasolli, Naim; Jeon, Seong-Min; Lee, Kang-San; Gang, Jun-Hyeok; Kim, Kwang-Deuk; Lee, Kwan-Young; Park, Young-Ok
- Issue Date
- 2월-2019
- Publisher
- MDPI
- Keywords
- sticky aerosol; calcium hydroxide; flow rate; filter; total collection efficiency
- Citation
- ATMOSPHERE, v.10, no.2
- Indexed
- SCIE
SCOPUS
- Journal Title
- ATMOSPHERE
- Volume
- 10
- Number
- 2
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/67764
- DOI
- 10.3390/atmos10020100
- ISSN
- 2073-4433
- Abstract
- This study examined the performance of removing aerosol upon a flow rate variable by agglomerating sticky aerosol with calcium hydroxide and removing cohesive aerosol through an experimental apparatus, simulating an actual painting booth. As a result of examining the performance of the filter by fixing the paint spray quantity, the calcium hydroxide input and the filtration area under variable flow rates of 5, 10, and 15 Nm(3)/min, we confirmed that the filter performance has long average aerosol removing intervals at the 5 Nm(3)/min flow rate. At the 5 Nm(3)/min flow rate, there is a low residual pressure drop trend and high fractional collection efficiency, and a high level of total collection efficiency is maintained at 99.42%. When the flow rate is less than 5 Nm(3)/min, the aerosol settling and experimentation was impossible. With this research, the optimal conditions for the use of sticky aerosol have been examined.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > Department of Chemical and Biological Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.