Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of ring 1 parameters in 37-segment multifocal electroretinography between onset and offset conditions of ring 2 to 4 in normal subjects

Authors
Yoo, Jun HoYun, CheolminOh, JaeryungKim, Seong-Woo
Issue Date
18-1월-2019
Publisher
IJO PRESS
Keywords
multifocal electroretinography; focal electroretinography; macular function; single element stimulation; stray light effect
Citation
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, v.12, no.1, pp.73 - 78
Indexed
SCIE
SCOPUS
Journal Title
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY
Volume
12
Number
1
Start Page
73
End Page
78
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/68267
DOI
10.18240/ijo.2019.01.11
ISSN
2222-3959
Abstract
AIM: To investigate whether the response of a central hexagonal element corresponding to the macular area in conventional multifocal electroretinography (mfERG) tests was the same as that of experimental mfERG using single central hexagonal element stimulation.. METHODS: Prospective, observational study. Thirty healthy subjects were included in this study. mfERG recordings were performed according to two protocols: stimulus with 37 hexagonal elements (protocol 1), and stimulus with a single central element created by deactivating the other 36 hexagonal elements (protocol 2). We compared differences between ring 1 parameters in each protocol.. RESULTS: In protocol 1, the first positive component (P1) implicit time and P1 amplitude were 37.8 +/- 1.8 ms and 6.3 +/- 2.7 mu V. After single element stimulation (protocol 2), double positive waves appeared. The implicit time and amplitude of P1 were 40.7 +/- 2.4 ms (P<0.001) and 9.1 +/- 3.3 mu V (P=0.001), respectively. The implicit time and amplitude of the second positive component (P2) were 68.0 +/- 4.5 ms (P<0.001, compared with P1 in protocol 1) and 12.3 +/- 4.7 mu V (P<0.001, compared with P1 in protocol 1), respectively. The amplitude of P2 in protocol 2 was about two times higher than that of P1 in protocol 1. CONCLUSION: mfERG responses of a central hexagonal element in a single element stimulation protocol are different from those of multiple element stimulation. The positive wave is more enhanced compared to that of the conventional protocol and it elongated into two wavelets.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Jae Ryung photo

Oh, Jae Ryung
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE