Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Electric stimulation-guided epidural analgesia for vaginal delivery: A randomized prospective study

Authors
Lee, Chung HunChoi, Sang SikLee, Mi KyoungKim, Jung EunChung, Dong IkLee, Mido
Issue Date
11-1월-2019
Publisher
PUBLIC LIBRARY SCIENCE
Citation
PLOS ONE, v.14, no.1
Indexed
SCIE
SCOPUS
Journal Title
PLOS ONE
Volume
14
Number
1
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/68307
DOI
10.1371/journal.pone.0209967
ISSN
1932-6203
Abstract
Background The failure rate of epidural anesthesia using the loss of resistance technique is 13-23%. Objectives To investigate the efficacy of epidural electric stimulation-guided epidural analgesia in vaginal delivery. Study design An open label randomized prospective study. Methods Laboring women were randomized to two groups: epidural catheter insertion using only a loss of resistance technique or a loss of resistance technique with confirmation by electric stimulation. Catheters in both groups were initially tested with 3 ml of 1% lidocaine and those with any evidence of motor blockade were considered intrathecal. Sensory blockade and an 11 point numerical rating score for pain were assessed 30 minutes after administration of an epidural bolus of 10 ml of 0.22% ropivacaine with fentanyl. Successful epidural analgesia was defined as a decrease of 2 or more in the pain score and a bilateral L1-T10 sensory blockade. Results Thirty-one patients were randomized to each group. The first 20 patients in each group were enrolled in a pilot study and were also included in the final analysis. One patient in the electric stimulation group was excluded owing to dural puncture by the Tuohy needle. One patient in each group demonstrated motor blockade after test dose and were considered failures. The number (% (95% confidence interval)) of successful cases were 29 out of 30 (97% (85, 100%)) in the electric stimulation group and 24 out of 31 (77% (61, 89%)) in the loss of resistance group (P = 0.053). However, analysis of only patients with absence of motor blockade revealed that 29 out of 29 (100% (92, 100%)) patients in the electric stimulation group and 24 of 29 (80% (63, 91%)) patients in the loss of resistance group had adequate analgesia (P = 0.024). Conclusions Although limited by lack of blinding, small study size and inclusion of pilot study data, this study suggests epidural electric stimulation improves the success rate of subsequent labor analgesia.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Sang Sik photo

Choi, Sang Sik
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE