Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The application of a vascular closure device for closing a gastrostomy opening used for procedural access

Authors
Cho, Sung BumKim, Hyoung RaeJung, Eui-ChulChung, Hwan HoonLee, Seung HwaPark, Beom JinSung, Deuk Jae
Issue Date
2019
Publisher
BRITISH INST RADIOLOGY
Citation
BRITISH JOURNAL OF RADIOLOGY, v.92, no.1099
Indexed
SCIE
SCOPUS
Journal Title
BRITISH JOURNAL OF RADIOLOGY
Volume
92
Number
1099
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/68974
DOI
10.1259/bjr.20180837
ISSN
0007-1285
Abstract
Objective: To study the feasibility of applying the Perclose ProGlide vascular closure device (PPVCD) in vitro for closing a gastrostomy opening for procedural access in the swine stomach in order to prevent peritoneal leakage. Methods: The study included four experimental groups: one manual suture (n = 10), two manual sutures (n = 10), one PPVCD suture (n = 10), and two PPVCD sutures (n = 5). In the two PPVCD sutures group, the "pre-close" technique was used. The leak pressure was measured, and statistical analysis was conducted to compare the leak pressures among the experimental groups. Results: The gastrostomy openings were successfully closed in all experimental groups. The median (range) values of leak pressure (mmHg) for each experimental group were as follows: one manual suture, 86.0 (75.0-110.0); two manual sutures, 98.5 (44.0-130. one PPVCD suture, 96.5 (56.0-119.0): and two PPVCD sutures, 98,0 (66.0-104.0). The Mann-Whitney U test revealed no statistically significant difference in leak pressure between the manual (n = 20) and PPVCD (n = 15) suture groups. The Kruskal-Wallis test revealed no statistically significant difference in leak pressure among the four experimental groups. The Bonferroni post hoc test also revealed no statistically significant difference in the pairwise comparisons among the groups. Conclusion: Application of PPVCD is feasible for the closure of gastrostomy openings in an animal model and is as effective as a manual suture. Advances in knowledge: In our in vitro study, percutaneous closure of gastrostomy opening using PPVCD was possible; animal survival studies and development of specific devices are needed before clinical application.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Beom jin photo

Park, Beom jin
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE