Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Validation of Pressure Reactivity and Pulse Amplitude Indices against the Lower Limit of Autoregulation: Part I: Experimental Intracranial Hypertension

Authors
Zeiler, Frederick A.Donnelly, JosephCalviello, LeanneLee, Jennifer K.Smielewski, PeterBrady, KenKim, Dong-JooCzosnyka, Marek
Issue Date
1-Dec-2018
Publisher
MARY ANN LIEBERT, INC
Keywords
autoregulation; continuous indices; experimental; LLA; validation
Citation
JOURNAL OF NEUROTRAUMA, v.35, no.23, pp.2803 - 2811
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF NEUROTRAUMA
Volume
35
Number
23
Start Page
2803
End Page
2811
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/71265
DOI
10.1089/neu.2017.5603
ISSN
0897-7151
Abstract
The purpose of this study was to provide validation of intracranial pressure (ICP) derived continuous indices of cerebrovascular reactivity against the lower limit of autoregulation (LLA). Utilizing an intracranial hypertension model within white New Zealand rabbits, ICP, transcranial Doppler (TCD), laser Doppler flowmetry (LDF), and arterial blood pressure were recorded. Data were retrospectively analyzed in a cohort of 12 rabbits with adequate signals for interrogating the LLA. We derived continuous indices of cerebrovascular reactivity: PRx (correlation between ICP and mean arterial pressure [MAP]), PAx (correlation between pulse amplitude of ICP [AMP] and MAP), and Lx (correlation between LDF-based cerebral blood flow [CBF] and cerebral perfusion pressure [CPP]). LLA was derived via piecewise linear regression of CPP versus LDF or CPP versus systolic flow velocity (FVs) plots. We then produced error bar plots for PRx, PAx, and Lx against 2.5mm Hg bins of CPP, to display the relationship between these indices and the LLA. We compared the CPP values at clinically relevant thresholds of PRx and PAx, to the CPP defined at the LLA. Receiver operating curve (ROC) analysis was performed for each index across the LLA using 2.5mm Hg bins for CPP. The mean LLA was 51.5 +/- 8.2mm Hg. PRx and PAx error bar plots demonstrate that each index correlates with the LLA, becoming progressively more positive below the LLA. Similarly, CPP values at clinically relevant thresholds of PRx and PAx were not statistically different from the CPP derived at the LLA. Finally, ROC analysis indicated that PRx and PAx predicted the LAA, with areas under the curve (AUCs) of 0.795 (95% confidence interval [CI]: 0.731-0.857, p<0.0001) and 0.703 (95% CI: 0.631-0.775, p<0.0001), respectively. Both PRx and PAx generally agree with LLA within this experimental model of intracranial hypertension. Further analysis of clinically used indices of autoregulation across the LLA within pure arterial hypotension models is required.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Brain and Cognitive Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE