Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Measuring Habitual Arm Use Post-stroke With a Bilateral Time-Constrained Reaching Task

Authors
Kim, SujinPark, HyeshinHan, Cheol E.Winstein, Carolee J.Schweighofer, Nicolas
Issue Date
22-Oct-2018
Publisher
FRONTIERS MEDIA SA
Keywords
stroke; hemiparesis; arm use; habitual choice; decision making
Citation
FRONTIERS IN NEUROLOGY, v.9
Indexed
SCIE
SCOPUS
Journal Title
FRONTIERS IN NEUROLOGY
Volume
9
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/72453
DOI
10.3389/fneur.2018.00883
ISSN
1664-2295
Abstract
Background: Spontaneous use of the more-affected arm is a meaningful indicator of stroke recovery. The Bilateral Arm Reaching Test (BART) was previously developed to quantify arm use by measuring arm choice to targets projected over a horizontal hemi-workspace. In order to improve clinical validity, we constrained the available movement time, thereby promoting more spontaneous decision making when selecting between the more-affected and less affected arm during the BART. Methods: Twenty-two individuals with mild to moderate hemiparesis were tested with the time-based BART in three time-constraint conditions: no-time constraint, medium, and fast conditions. Arm use was measured across three sessions with a 2-week interval in a spontaneous choice block, in which participants were instructed to use either the more-affected or the less-affected arm to reach targets. We tested the effect of time-constraint condition on the more-affected arm use, external validity of the BART with the Actual Amount of Use Test (AAUT), and test-retest reliability across the three test sessions. Results: The fast condition in the time-based BART showed reduced use of the more-affected arm compared to the no-time constraint condition (P < 0.0001) and the medium condition (P = 0.0006; Tukey post hoc analysis after mixed-effect linear regression). In addition, the fast condition showed strong correlation with the AAUT (r = 0.829, P < 0.001), and excellent test-retest reliability (ICC = 0.960, P < 0.0001). Conclusion: The revised BART with a time-restricted fast condition provides an objective, accurate, and repeatable measure of spontaneous arm use in individuals with chronic stroke hemiparesis.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Electronics and Information Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE