Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique

Authors
Kang, Seen-YoungPark, Jung-HyunKim, Ji-HwanKim, Woong-Chul
Issue Date
Oct-2018
Publisher
KOREAN ACAD PROSTHODONTICS
Keywords
Stereolithography apparatus; Subtractive technology; Provisional crown; CAD/CAM system
Citation
JOURNAL OF ADVANCED PROSTHODONTICS, v.10, no.5, pp.354 - 360
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF ADVANCED PROSTHODONTICS
Volume
10
Number
5
Start Page
354
End Page
360
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/72590
DOI
10.4047/jap.2018.10.5.354
ISSN
2005-7806
Abstract
PURPOSE. To compare and analyze trueness and precision of provisional crowns made using stereolithography apparatus and subtractive technology. MATERIALS AND METHODS. Digital impressions were made using a master model and an intraoral scanner and the crowns were designed with CAD software; in total, 22 crowns were produced. After superimposing CAD design data and scan data using a 3D program, quantitative and qualitative data were obtained for analysis of trueness and precision. Statistical analysis was performed using normality test combined with Levene test for equal variance analysis and independent sample t-test. Type 1 error was set at 0.05. RESULTS. Trueness for the outer and inner surfaces of the SLA crown (SLAG) were 49.6 +/- 9.3 mu m and 22.5 +/- 5.1 mu m, respectively, and those of the subtractive crown (SUBC) were 31.8 +/- 7.5 mu m and 14.6 +/- 1.2 mu m, respectively. Precision values for the outer and inner surfaces of the SLAC were 18.7 +/- 6.2 mu m and 26.9 +/- 8.5 pm, and those of the SUBC were 25.4 +/- 3.1 mu m and 13.8 +/- 0.6 mu m, respectively. Trueness values for the outer and inner surfaces of the SLAC and SUBC showed statistically significant differences (P<.001). Precision for the inner surface showed significance (P<.03), whereas that for the outer surface showed no significance (P<.58). CONCLUSION. The study demonstrates that provisional crowns produced by subtractive technology are superior to crowns fabricated by stereolithography in terms of accuracy.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
College of Health Sciences (Division of Health Policy and Management)
Read more

Altmetrics

Total Views & Downloads

BROWSE