Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Study of Thin Double-Gap RPCs for the CMS Muon System

Authors
Lee, K. S.Cho, S. W.Choi, S.Hong, B.Kang, M.Lim, J. H.Jo, Y. M.Park, S. K.Ryoo, K. R.Aly, R.Aly, S.Assran, Y.Mohamed, A.Mahrous, A.Constantini, S.Abbrescia, M.Gelmi, A.Maggi, M.Iaselli, G.Pugliese, G.Sharma, A.Bhatnagar, V.Gupta, R.Kumari, P.Manisha, M.Singh, J.Benussi, L.Bianc, S.Piccolo, D.Primavera, F.Fagot, A.Gul, M.Roskas, C.Tytgat, M.Zagandis, N.Pant, L.Buontempo, S.Buonaura, A.Di Crescenzo, A.Fienga, F.Galati, G.Lista, L.Meola, S.Orso, A.Paolucci, P.Voevodina, E.Hoorani, H.Muhammad, S.Shah, M.Braghieri, A.Montagna, P.Riccardi, C.Salvini, P.Vitulo, P.Ban, Y.Qian, S.Aleksandrov, A.Hadjiiska, R.Iaydjiev, P.Rodozov, M.Soultanov, G.Vutiva, M.Dimitrov, A.Litov, L.Petkov, P.Dimitrov, A.Pavlov, B.Han, D.Wang, Y.Bernal, C.Carrillo Montoya, C.Cabrera Mora, A.Gouzevitch, M.Grenier, G.Lagarde, F.Laktineh, I.Uribe Estrada, C.Eysermans, J.Pedraza, I.Bagaturia, I.Lomidze, D.Lomidze, I.Tsamalaidze, Z.Toriashvili, T.Carrillo Moreno, S.Vazquez Valencia, F.Goh, J.Jeong, S.Kim, T.Yu, I.Hwang, C.Mohammadi, M.NajafabadiBoghrati, B.Castilla-Valdez, H.Sanchez-Hernandez, A.Crotty, I.
Issue Date
Oct-2018
Publisher
KOREAN PHYSICAL SOC
Keywords
Resistive plate chambers; Compact Muon Solenoid; Large Hadron Collider; Muon triggers
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.73, no.8, pp.1080 - 1087
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
73
Number
8
Start Page
1080
End Page
1087
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/72656
DOI
10.3938/jkps.73.1080
ISSN
0374-4884
Abstract
High-sensitivity double-gap phenolic resistive plate chambers (RPCs) are studied for the Phase-2 upgrade of the Compact Muon Solenoid (CMS) muon system at high pseudorapidity . Whereas the present CMS RPCs have a gas gap thickness of 2 mm, we propose to use thinner gas gaps, which will improve the performance of these RPCs. To validate this proposal, we constructed double-gap RPCs with two different gap thicknesses of 1.2 and 1.4 mm by using high-pressure laminated plates having a mean resistivity of about 5 x 10(10) -cm. This paper presents test results using cosmic muons and Cs-137 gamma rays. The rate capabilities of these thin-gap RPCs measured with the gamma source exceed the maximum rate expected in the new high- endcap RPCs planned for future Phase-2 runs of the Large Hadron Collider (LHC).
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHOI, Su yong photo

CHOI, Su yong
College of Science (Department of Physics)
Read more

Altmetrics

Total Views & Downloads

BROWSE