Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Control Variable Implants Improve Interpretation of Surface Modification and Implant Design Effects on Early Bone Responses: An In Vivo Study

Authors
Choi, Jung-YooKang, Seok-HyungKim, Hae-YoungYeo, In-Sung Luke
Issue Date
9월-2018
Publisher
QUINTESSENCE PUBLISHING CO INC
Keywords
control variable; fluoride-modified; hydrophilic SLA; implant design; SLA
Citation
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, v.33, no.5, pp.1033 - 1040
Indexed
SCIE
SCOPUS
Journal Title
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
Volume
33
Number
5
Start Page
1033
End Page
1040
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/73185
DOI
10.11607/jomi.6436
ISSN
0882-2786
Abstract
Purpose: This in vivo study used control variable implants to compare early bone responses in fluoride-modified (F-mod) and hydrophilic, sandblasted, large-grit, acid-etched (modSLA) surface implants that differed in implant design. Materials and Methods: Four different types of implants (n = 24) were prepared: F-mod surface with Astra Tech implant design; modSLA surface with Straumann implant design; sandblasted, large-grit, acid-etched (SLA) surface with Astra Tech design; and SLA surface with Straumann implant design. Scanning electron microscopy, confocal laser scanning microscopy, and x-ray photoelectron spectroscopy were performed to assess implant surface characteristics. Four implants from each implant type were inserted in the tibiae of four rabbits that were sacrificed 10 days after surgery. Bone-to-implant contact (BIC) and bone area (BA) were measured to evaluate early bone responses. Analysis of variance with Tukey's multiple comparison method was used for the histomorphometric data to find any significant difference. The surface characteristic-related data were analyzed using the Kruskal-Wallis test. The level of significance was .05 in statistical analyses. Results: No significant differences in BIC and BA were found among the modified surfaces (P > .05), whereas significant differences were found in surface topography and surface chemistry. The different designs showed no significant effects on early bone responses when identical surface modifications were applied (P > .05). Conclusion: F-mod and modSLA surfaces showed no significant differences in early bone responses. Furthermore, the implant design had no influence on the bone response. This in vivo experimental model will help improve the evaluation of surface modification factors by allowing an independent estimation of one variable (surface modification) against a constant (implant design).
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hae Young photo

Kim, Hae Young
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE