Development of Raman Lidar for Remote Sensing of CO2 Leakage at an Artificial Carbon Capture and Storage Site
- Authors
- Kim, Daewon; Kang, Hyeongwoo; Ryu, Jea-Yong; Jun, Seong-Chun; Yun, Seong-Taek; Choi, SungChul; Park, SunHo; Yoon, MoonSang; Lee, Hanlim
- Issue Date
- 9월-2018
- Publisher
- MDPI
- Keywords
- CO2; Raman lidar; Carbon capture and storage; CO2 leakage remote sensing
- Citation
- REMOTE SENSING, v.10, no.9
- Indexed
- SCIE
SCOPUS
- Journal Title
- REMOTE SENSING
- Volume
- 10
- Number
- 9
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/73222
- DOI
- 10.3390/rs10091439
- ISSN
- 2072-4292
- Abstract
- We developed a Raman lidar system that can remotely detect CO2 leakage and its volume mixing ratio (VMR). The system consists of a laser, a telescope, an optical receiver, and detectors. Indoor CO2 cell measurements show that the accuracy of the Raman lidar is 99.89%. Field measurements were carried out over a four-day period in November 2017 at the Eumsong Environmental Impact Evaluation Test Facility (EIT), Korea, where a CO2 leak was located 0.2 km from the Raman lidar. The results show good agreement between CO2 VMR measured by the Raman lidar system (CO2 VMRRaman LIDAR) and that measured by in situ instruments (CO2 VMRIn-situ) The correlation coefficient (R), mean absolute error (MAE), root mean square error (RMSE), and percentage difference between CO2 VMRin-situ and CO2 VMRRaman LIDAR are 0.81, 0.27%, 0.37%, and 4.92%, respectively. The results indicate that Raman lidar is an effective tool in detecting CO2 leakage and in measuring CO2 VMR remotely.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Science > Department of Earth and Environmental Sciences > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.