Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fluorescent image-based evaluation of gastric conduit perfusion in a preclinical ischemia model

Authors
Quan, Yu HuaKim, MinjiKim, Hyun KooKim, Beop-Min
Issue Date
9월-2018
Publisher
AME PUBL CO
Keywords
Gastric conduit ischemic model; perfusion; esophagectomy
Citation
JOURNAL OF THORACIC DISEASE, v.10, no.9, pp.5359 - +
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF THORACIC DISEASE
Volume
10
Number
9
Start Page
5359
End Page
+
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/73291
DOI
10.21037/jtd.2018.08.46
ISSN
2072-1439
Abstract
Background: This study evaluated near-infrared (NIR) fluorescent images to assess gastric conduit perfusion after an esophagectomy in a porcine model of gastric conduit ischemia. The time necessary to acquire a sufficient fluorescent signal to confirm ischemia in the gastric conduit after peripheral or central venous injection of indocyanine green (ICG) was also investigated. Methods: A reversible gastric conduit ischemic pig model was established through ligation and release of the right gastroepiploic artery (RGEA, n=10). The esophageal reconstruction was performed to create an esophagogastric anastomosis. After ligation of the RGEA, ICG was injected into an ear vein (n=6) or the inferior vena cava (n=4). Under fluorescent imaging system guidance, the fluorescent signal-to-background ratio (SBR) in the gastric conduit or esophagus was measured during the entire procedure. We estimated the time necessary to acquire fluorescent signals in the gastric conduit using two different injection routes. Results: When the RGEA was ligated, the SBR in the esophagus was significantly higher than that in the gastric conduit (P=0.02), and the SBR in the gastric conduit recovered within 180 s after release of the ligation. The time to acquire a fluorescent signal was faster with a central route than with a peripheral route (P=0.04). Conclusions: We successfully created an ischemic animal model of the gastric conduit. Using this animal model, we evaluated the sensitivity and applicability of the fluorescent imaging system for observation and identification of ischemic areas during an esophagectomy.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyun Koo photo

Kim, Hyun Koo
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE