Three-Dimensional Terahertz Tomography With Transistor-Based Signal Source and Detector Circuits Operating Near 300 GHz
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Jungsoo | - |
dc.contributor.author | Yoon, Daekeun | - |
dc.contributor.author | Yun, Jongwon | - |
dc.contributor.author | Song, Kiryong | - |
dc.contributor.author | Kaynak, Mehmet | - |
dc.contributor.author | Tillack, Bernd | - |
dc.contributor.author | Rieh, Jae-Sung | - |
dc.date.accessioned | 2021-09-02T07:26:06Z | - |
dc.date.available | 2021-09-02T07:26:06Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2018-09 | - |
dc.identifier.issn | 2156-342X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/73646 | - |
dc.description.abstract | In this paper, three-dimensional (3-D) terahertz (THz) tomography was demonstrated with a signal source and imagers based on transistor circuits fabricated with standard semiconductor technologies. For the signal source, a 300-GHz oscillator based on InP HBT technology was employed. For detection, two types of imagers operating near 300 GHz were employed, one direct and the other heterodyne, both realized with SiGe HBT technology. With a set of 2-D images taken from different angles, sinograms and tomograms were obtained, which led to a successful reconstruction of 3-D images of the target object based on the filtered back-projection algorithm. A systematic comparison was made for the direct imager and the heterodyne imager, for which the signal input power and the video bandwidth were varied for both imagers. The results revealed that the heterodyne imager shows a better sensitivity than the direct imager. However, a similar dynamic range of around 30 dB was achieved for both imagers because of a saturation observed for the heterodyne imager when the input power exceeds the threshold. The video bandwidth did not affect the image quality significantly for the bandwidth variation over four orders of magnitude for both imagers. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.subject | COMPUTED-TOMOGRAPHY | - |
dc.subject | IMAGING APPLICATIONS | - |
dc.subject | TECHNOLOGY | - |
dc.subject | CMOS | - |
dc.title | Three-Dimensional Terahertz Tomography With Transistor-Based Signal Source and Detector Circuits Operating Near 300 GHz | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Rieh, Jae-Sung | - |
dc.identifier.doi | 10.1109/TTHZ.2018.2851542 | - |
dc.identifier.scopusid | 2-s2.0-85049149834 | - |
dc.identifier.wosid | 000444569500002 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON TERAHERTZ SCIENCE AND TECHNOLOGY, v.8, no.5, pp.482 - 491 | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON TERAHERTZ SCIENCE AND TECHNOLOGY | - |
dc.citation.title | IEEE TRANSACTIONS ON TERAHERTZ SCIENCE AND TECHNOLOGY | - |
dc.citation.volume | 8 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 482 | - |
dc.citation.endPage | 491 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Optics | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Optics | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordPlus | COMPUTED-TOMOGRAPHY | - |
dc.subject.keywordPlus | IMAGING APPLICATIONS | - |
dc.subject.keywordPlus | TECHNOLOGY | - |
dc.subject.keywordPlus | CMOS | - |
dc.subject.keywordAuthor | Imaging | - |
dc.subject.keywordAuthor | receivers | - |
dc.subject.keywordAuthor | tomography | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.