Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Stretchable array of high-performance micro-supercapacitors charged with solar cells for wireless powering of an integrated strain sensor

Authors
Yun, JunyeongSong, ChanghoonLee, HanchanPark, HeunJeong, Yu RaKim, Jung WookJin, Sang WooOh, Seung YunSun, LianfangZi, GoangseupHa, Jeong Sook
Issue Date
7월-2018
Publisher
ELSEVIER SCIENCE BV
Keywords
Stretchable; Micro-supercapacitor; Strain sensor; Solar cell; Integration; Self-charge system
Citation
NANO ENERGY, v.49, pp.644 - 654
Indexed
SCIE
SCOPUS
Journal Title
NANO ENERGY
Volume
49
Start Page
644
End Page
654
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/74432
DOI
10.1016/j.nanoen.2018.05.017
ISSN
2211-2855
Abstract
The aim of this paper is to report on the fabrication of a stretchable array of high-performance solid-state microsupercapacitors (MSCs), which can be charged with integrated, commercial Si-based solar cells (SCs). This would facilitate the powering of an integrated strain sensor. The planar MSCs comprised electrodes of potentiostatically deposited polypyrrole, on spray-coated multi-walled carbon nanotube film, and a gel-type electrolyte of LiCl/polyvinyl alcohol with a redox additive of 1-methyl-3-propylimidazolium iodide. The fabricated MSC achieved an areal capacitance of 5.17 mF cm(-2). After 5000 charge/discharge cycles, the MSC retained 80% of their initial capacitance. A strain sensor was fabricated utilizing a composite film of fragmentized graphene foam and polydimethylsiloxane. Such fabricated twelve parallel connected MSCs, a strain sensor, and SCs were integrated on a single deformable polymer substrate with embedded stiff platforms of negative epoxy series resist (SU-8) via long serpentine interconnections of polyimide encapsulated Ti/Pt metal film for mechanical stability under stretching. After 1000 repetitive biaxial stretching/releasing cycles by 30%, no noticeable change was observed in the charge/discharge behavior of the MSC array. Furthermore, both the photo-charge/discharge characteristics and electrochemical performance remained stable. When the whole integrated system was attached to the wrist, the integrated strain sensor could detect both externally applied strain and the arterial pulse using the energy stored in the MSCs from the SCs.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles
College of Engineering > Department of Chemical and Biological Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ha, Jeong Sook photo

Ha, Jeong Sook
공과대학 (화공생명공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE