Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Stimulation Efficiency With Decaying Exponential Waveforms in a Wirelessly Powered Switched-Capacitor Discharge Stimulation System

Authors
Lee, Hyung-MinHowell, BryanGrill, Warren M.Ghovanloo, Maysam
Issue Date
5월-2018
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Implantable pulse generator; stimulation efficiency; switched-capacitor discharging stimulation; wireless power transmission
Citation
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, v.65, no.5, pp.1095 - 1106
Indexed
SCIE
SCOPUS
Journal Title
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume
65
Number
5
Start Page
1095
End Page
1106
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/75622
DOI
10.1109/TBME.2017.2741107
ISSN
0018-9294
Abstract
The purpose of this study was to test the feasibility of using a switched-capacitor discharge stimulation (SCDS) system for electrical stimulation, and, subsequently, determine the overall energy saved compared to a conventional stimulator. We have constructed a computational model by pairing an image-based volume conductor model of the cat head with cable models of corticospinal tract (CST) axons and quantified the theoretical stimulation efficiency of rectangular and decaying exponential waveforms, produced by conventional and SCDS systems, respectively. Subsequently, the model predictions were tested in vivo by activating axons in the posterior internal capsule and recording evoked electromyography (EMG) in the contralateral upper arm muscles. Compared to rectangular waveforms, decaying exponential waveforms with time constants > 500 mu s were predicted to require 2%-4% less stimulus energy to activate directly models of CST axons and 0.4%-2% less stimulus energy to evoke EMG activity in vivo. Using the calculated wireless input energy of the stimulation system and the measured stimulus energies required to evoke EMG activity, we predict that an SCDS implantable pulse generator (IPG) will require 40% less input energy than a conventional IPG to activate target neural elements. A wireless SCDS IPG that is more energy efficient than a conventional IPG will reduce the size of an implant, require that less wireless energy be transmitted through the skin, and extend the lifetime of the battery in the external power transmitter.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Hyung Min photo

Lee, Hyung Min
공과대학 (전기전자공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE