Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Eye Drop Dispenser Type and Medication Possession Ratio in Patients With Glaucoma: Single-Use Containers Versus Multiple-Use Bottles

Authors
Na, Kun-HooYoo, ChungkwonPark, Ji-HyeKim, Yong Yeon
Issue Date
Apr-2018
Publisher
ELSEVIER SCIENCE INC
Keywords
Glaucoma
Citation
AMERICAN JOURNAL OF OPHTHALMOLOGY, v.188, pp.9 - 18
Indexed
SCIE
SCOPUS
Journal Title
AMERICAN JOURNAL OF OPHTHALMOLOGY
Volume
188
Start Page
9
End Page
18
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/76194
DOI
10.1016/j.ajo.2018.01.011
ISSN
0002-9394
Abstract
PURPOSE: To determine whether the consumption of topical glaucoma medication is influenced by the type of eye drop dispenser. DESIGN: Retrospective cohort study. METHODS: We examined 366 patients with open-angle glaucoma or ocular hypertension who were bilaterally treated with 0.0015% tafluprost or 2% dorzolamide/0.5% timolol fixed combination (DTFC). The patients were grouped by the type of dispenser and content of eye drops used: (1) tafluprost in bottles (T-Bottle group); (2) tafluprost in unit-dose pipettes (T-Unit group); (3) DTFC in bottles (C-Bottle group); and (4) DTFC in unit-dose pipettes (C-Unit group). We evaluated the medication possession ratio (MPR) among groups, and factors associated with over-consumption (MPR > 1.2) or under-consumption (MPR < 0.8) in multinomial logistic regression. RESULTS: The mean MPR was 1.49 (range, 0.69-2.91) in the T-Bottle group, 0.91 (range, 0.32-1.27) in the T-Unit group, 1.25 (range, 0.51-2.60) in the C-Bottle group, and 0.96 (range, 0.36-1.60) in the C-Unit group. The Bottle groups demonstrated higher mean values and wider ranges of MPR compared to the Unit groups. The MPR interval at which the largest number of patients were found was 1.0-1.4 in the Bottle groups and 0.8-1.2 in the Unit groups. Bottle-type dispenser (odds ratio [OR] 64.02), tafluprost medication (OR 2.84), and older age (OR 1.03) were associated with over-consumption, whereas no factor was correlated with under-consumption. CONCLUSIONS: The type of eye drop dispenser affects the consumption of glaucoma medication. Physicians should consider the type of eye drop dispenser when assessing glaucoma medication adherence. ((c) 2018 Elsevier Inc. All rights reserved.)
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Chung kwon photo

Yoo, Chung kwon
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE