Use and Limitations of Offsite Consequence Analysis Tools from South Korea and the United States in Hydrogen Fluoride Accidental Release

Authors
Kim, Min-UkByeon, Sang-Hoon
Issue Date
3월-2018
Publisher
WILEY
Keywords
Offsite consequence analysis; KORA; RMP*Comp; ALOHA; Operating conditions
Citation
INTEGRATED ENVIRONMENTAL ASSESSMENT AND MANAGEMENT, v.14, no.2, pp.205 - 211
Indexed
SCIE
SCOPUS
Journal Title
INTEGRATED ENVIRONMENTAL ASSESSMENT AND MANAGEMENT
Volume
14
Number
2
Start Page
205
End Page
211
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/76802
DOI
10.1002/ieam.2019
ISSN
1551-3777
Abstract
We investigated the characteristics and limitations in the event of hydrofluoric acid (HF) leakage by comparing and analyzing the offsite consequence analysis (OCA) tools based on the chemical plant operating conditions. We reviewed the tools Korea Offsite Risk Assessment (KORA) from South Korea and Risk Management Plan*Comp (RMP*Comp (TM)) and Areal Location of Hazardous Atmospheres (ALOHA) from the United States. The scenario studied was based on a leak event from a 50% HF aqueous solution storage tank, and the operating conditions taken into consideration were the operating temperature and dike installation conditions. The results from the OCA differed; KORA presented a smaller range of offsite impact than did ALOHA. The offsite impact ranges of KORA and ALOHA increased as the operating temperature and dike installation area increased. However, RMP*Comp differed greatly in its offsite impact range results in the operating temperature range of 25 degrees C to 30 degrees C. Moreover, in the alternative scenario, a limitation existed in that the offsite impact range was not changed by the dike installation conditions. The offsite impact range analyzed via KORA and ALOHA reflected the reality of an HF leak accident better than that analyzed via RMP*Comp. Therefore, it is more reasonable to use KORA and ALOHA instead of RMP*Comp in OCA. Moreover, users should realize that ALOHA has a somewhat wider range of offsite impact than KORA does in OCA. The separation distance from the storage tank when installing a dike is effective between 1 and 1.5m in consideration of securing the minimum workspace for workers.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Byeon, Sang Hoon photo

Byeon, Sang Hoon
보건과학대학 (보건환경융합과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE