Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Cost-effective Light Emitting Diode-acoustic System for Preclinical Ocular Applications

Authors
Choi, HojongRyu, JaemyungYeom, Jung-Yeol
Issue Date
25-Feb-2018
Publisher
OPTICAL SOC KOREA
Keywords
Ramsden eyepiece; Bovine; Bigeye tuna; Ultrasound transducers
Citation
CURRENT OPTICS AND PHOTONICS, v.2, no.1, pp.59 - 68
Indexed
SCIE
SCOPUS
KCI
Journal Title
CURRENT OPTICS AND PHOTONICS
Volume
2
Number
1
Start Page
59
End Page
68
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/77313
DOI
10.3807/COPP.2018.2.1.059
ISSN
2508-7266
Abstract
Opto-acoustic systems provide structural and functional information regarding biological tissues. Conventional opto-acoustic systems typically employ continuous or pulsed lasers as transmission sources. Compared to lasers, light emitting diodes (LEDs) are cost-effective and relatively portable excitation sources but are non, coherent. Therefore, in this study, a relatively low cost lens - a type of Ramsden eyepiece - was specially designed to theoretically calculate the illumination and achieve a constant brightness across the pupil of an eye. In order to verify the capability of the developed light-emitting diode-acoustic (LEDA) systems, we carried out experiments on bovine and bigeye tuna eyeball samples, which are of similar size to the human eye, using low frequency (10 MHz) and high frequency (25 MHz) ultrasound transducers. High frequency ultrasound transducers are able to provide higher spatial resolution compared to low frequency ultrasound transducers at the expense of penetration depth. Using the 10 MHz and 25 MHz ultrasound transducers, acceptable echo signals (3.82, 3.94, and 5.84 mV at 10 MHz and 282, 1557, 2356 mV at 25 MHz) from depth greater than 3 cm and 6 cm from the anterior surface of the eye were obtained. We thereby confirmed that the LEDA system using a pulsed LED with the designed Ramsden eyepiece lens, used in conjunction with low and high frequency ultrasound transducers, has the potential to be a cost-effective alternative method, while providing adequate acoustic signals from bovine and bigeye tuna ocular areas.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.