Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Engineering chart for thermal performance of cast-in-place energy pile considering thermal resistance

Authors
Park, SangwooLee, SeokjaeOh, KwanggeunKim, DongkuChoi, Hangseok
Issue Date
5-2월-2018
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Ground heat exchanger (GHEX); Geothermal energy; Cast-in-place energy pile; Computational fluid dynamic (CFD) analysis; Engineering chart
Citation
APPLIED THERMAL ENGINEERING, v.130, pp.899 - 921
Indexed
SCIE
SCOPUS
Journal Title
APPLIED THERMAL ENGINEERING
Volume
130
Start Page
899
End Page
921
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/77386
DOI
10.1016/j.applthermaleng.2017.11.065
ISSN
1359-4311
Abstract
An energy pile is one of the novel types of ground heat exchanger (GHEX), which has been introduced as an economical alternative to conventional closed-loop vertical GHEXs. The energy pile contains heat exchange pipes inside a pile foundation and circulates a working fluid through the pipe inducing heat exchange with the surrounding ground formation. Using the existing foundation structure, the energy pile can reduce the initial construction cost such as drilling and grouting cost, and eliminate the need for additional construction space. However, most commercial design programs and analytical models for estimating the thermal performance of GHEXs are mainly applicable to the closed-loop vertical GHEXs. In this paper, an engineering chart is proposed for evaluating the thermal performance of cast in-place energy piles considering various layouts of heat exchange pipe. First, parametric studies on different ground and operation conditions were performed with the aid of a series of computational fluid dynamic (CFD) analyses to determine design factors of the cast-in-place energy pile. Based on the design factors, the engineering chart for the thermal performance of cast-in-place energy piles was developed. Since the CFD simulations were exclusively carried out for the typical 5-pair-parallel U-type energy pile, the concept of thermal resistance was adopted for estimating the thermal performance of other types of cast-in-place energy piles. The accuracy of the developed engineering chart was verified by comparing with the results of CFD simulations, and the maximum error was measured to be about 9%. (C) 2017 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHOI, HANG SEOK photo

CHOI, HANG SEOK
공과대학 (건축사회환경공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE