Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of Osmolarity of Various Artificial Tears Products Commercially Available in South Korea

Authors
Woo, In HoHong, Jun GiHuh, Jung AhEom, YoungsubKim, Hyo MyungSong, Jong Suk
Issue Date
2월-2018
Publisher
KOREAN OPHTHALMOLOGICAL SOC
Keywords
Artificial tears; Dry eye; Osmolarity; TearLab (R)
Citation
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, v.59, no.2, pp.117 - 122
Indexed
SCOPUS
KCI
Journal Title
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY
Volume
59
Number
2
Start Page
117
End Page
122
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/77893
DOI
10.3341/jkos.2018.59.2.117
ISSN
0378-6471
Abstract
Purpose: To compare the osmolarity of various artificial tear products commercially available in the Republic of Korea. Methods: The osmolarity of the artificial tears was analyzed using TearLab (R) and Multi-Osmette (TM). We divided the artificial tear products into five groups, including hypo-osmolar 0.18% sodium hyaluronate (HA), iso-osmolar 0.1%, 0.15%, 0.3% HA, and 0.5% carboxymethylcellulose sodium (CMC), and measured three products per group. Results: Among the 12 products of iso-osmolar artificial tears, there were seven products (58.3%) < 300 mOsm/L, and among the three products of hypo-osmolar artificial tears, there were two products (66.6%) < 150 mOsm/L. A significant difference (p < 0.05) was observed between the iso-osmolar 0.3% HA group and the hypo-osmolar 0.18% HA group. In the iso-osmolar 0.1% HA and 0.15% HA, the difference between the products in each group was approximately 12 mOsm/L, and the CMC group had the smallest deviation among products, which was close to 300 mOsm/L. There was a significant difference of 305.57 +/- 6.38 mOsm/L in the iso-osmolar 0.15% HA group, 293.44 +/- 8.71 mOsm/L in the 0.1% HA group, and 285.67 +/- 3.67 mOsm/L in the 0.3% HA group (p < 0.001). There was no significant difference in osmolarity between the iso-osmolar products containing HA and CMC (p = 0.117). Conclusions: There was a difference in osmolarity between the published and actual measured values of commercial artificial tears, and there was a difference in osmolality depending on the content of HA and the manufacturer.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE