Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development of flexible glucose measurement sensor based on copper nanocubes electroplated laser induced graphene electrode

Authors
Kim, G.-J.Kim, T.Pak, J.
Issue Date
2018
Publisher
Korean Institute of Electrical Engineers
Keywords
Copper nanocubes; Flexible sensor; Glucose; Laser induced graphene; LIG
Citation
Transactions of the Korean Institute of Electrical Engineers, v.67, no.3, pp.413 - 418
Indexed
SCOPUS
KCI
Journal Title
Transactions of the Korean Institute of Electrical Engineers
Volume
67
Number
3
Start Page
413
End Page
418
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/80389
DOI
10.5370/KIEE.2018.67.3.413
ISSN
1975-8359
Abstract
In this paper, we describe the development of a non-enzymatic glucose sensor based on copper nanocubes(Cu NCs) electroplated laser induced graphene(LIG) electrodes which can detect a certain range of glucose concentrations. CO2 laser equipment was used to form LIG electrodes on the PI film. This fabrication method allows easy control of the LIG electrode size and shape. The Cu NCs were electrochemically deposited on the LIG electrodes to improve electron transfer rates and thus enhancing electrocatalytic reaction with glucose. The average sheet resistances before and after electroplating were 15.6 Ω/□ and 19.6 Ω/□, respectively, which confirmed that copper nanocubes were formed on the laser induced graphene electrodes. The prepared electrode was used to measure the current according to glucose concentration using an electrochemical method. The LIG electrodes with Cu NCs demonstrated a high degree of sensitivity (1643.31 μA/mM.cm2), good stability with a linear response to glucose ranging from 0.05 mM to 1 mM concentration, and a limit of detection of 0.05 mM. In order to verify that these electrodes can be used as flexible devices, the electrodes were bent to 30°, 90°, and 180° and cyclic voltammetry measurements were taken while the electrodes were bent. The measured data showed that the peak voltage was almost constant at 0.42 V and the signal was stable even in the flexed condition. Therefore, it is concluded that these electrodes can be used in flexible sensors for detecting glucose in the physiological sample like saliva, tear or sweat. © Copyright The Korean Institute of Electrical Engineers.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Pak, James Jung ho photo

Pak, James Jung ho
공과대학 (전기전자공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE