Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance Prediction of Centrifugal Compressor for Drop-In Testing Using Low Global Warming Potential Alternative Refrigerants and Performance Test Codes

Authors
Park, Joo HoonShin, YouhwanChung, Jin Taek
Issue Date
12월-2017
Publisher
MDPI
Keywords
operating range; operating point; centrifugal compressor; low-GWP alternative refrigerant; R-1234ze (E); R-1233zd (E); drop-in test; performance test code
Citation
ENERGIES, v.10, no.12
Indexed
SCIE
SCOPUS
Journal Title
ENERGIES
Volume
10
Number
12
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/81280
DOI
10.3390/en10122043
ISSN
1996-1073
Abstract
As environmental regulations to stall global warming are strengthened around the world, studies using newly developed low global warming potential (GWP) alternative refrigerants are increasing. In this study, substitute refrigerants, R-1234ze (E) and R-1233zd (E), were used in the centrifugal compressor of an R-134a 2-stage centrifugal chiller with a fixed rotational speed. Performance predictions and thermodynamic analyses of the centrifugal compressor for drop-in testing were performed. A performance prediction method based on the existing ASME PTC-10 performance test code was proposed. The proposed method yielded the expected operating area and operating point of the centrifugal compressor with alternative refrigerants. The thermodynamic performance of the first and second stages of the centrifugal compressor was calculated as the polytropic state. To verify the suitability of the proposed method, the drop-in test results of the two alternative refrigerants were compared. The predicted operating range based on the permissible deviation of ASME PTC-10 confirmed that the temperature difference was very small at the same efficiency. Because the drop-in test of R-1234ze (E) was performed within the expected operating range, the centrifugal compressor using R-1234ze (E) is considered well predicted. However, the predictions of the operating point and operating range of R-1233zd (E) were lower than those of the drop-in test. The proposed performance prediction method will assist in understanding thermodynamic performance at the expected operating point and operating area of a centrifugal compressor using alternative gases based on limited design and structure information.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHUNG, Jin Taek photo

CHUNG, Jin Taek
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE