Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

Authors
Kim, Dong-YeonKim, Eo-BinKim, Hae-YoungKim, Ji-HwanKim, Woong-Chul
Issue Date
12월-2017
Publisher
KOREAN ACAD PROSTHODONTICS
Keywords
CAD/CAM; Micro-stereolithography; Metal framework; Marginal gap; Internal gap
Citation
JOURNAL OF ADVANCED PROSTHODONTICS, v.9, no.6, pp.463 - 469
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF ADVANCED PROSTHODONTICS
Volume
9
Number
6
Start Page
463
End Page
469
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/81303
DOI
10.4047/jap.2017.9.6.463
ISSN
2005-7806
Abstract
PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and threedimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (alpha=. 05). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<. 001). In the marginal area where pontic was present, the largest gap was 149.39 +/- 42.30 mu m in the AM group, and the lowest gap was 24.40 +/- 11.92 mu m in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hae Young photo

Kim, Hae Young
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE