Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Real-time robustness evaluation of regression based myoelectric control against arm position change and donning/doffing

Authors
Hwang, Han-JeongHahne, Janne MathiasMueller, Klaus-Robert
Issue Date
2-Nov-2017
Publisher
PUBLIC LIBRARY SCIENCE
Citation
PLOS ONE, v.12, no.11
Indexed
SCIE
SCOPUS
Journal Title
PLOS ONE
Volume
12
Number
11
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/81587
DOI
10.1371/journal.pone.0186318
ISSN
1932-6203
Abstract
There are some practical factors, such as arm position change and donning/doffing, which prevent robust myoelectric control. The objective of this study is to precisely characterize the impacts of the two representative factors on myoelectric controllability in practical control situations, thereby providing useful references that can be potentially used to find better solutions for clinically reliable myoelectric control. To this end, a real-time target acquisition task was performed by fourteen subjects including one individual with congenital upper-limb deficiency, where the impacts of arm position change, donning/doffing and a combination of both factors on control performance was systematically evaluated. The changes in online performance were examined with seven different performance metrics to comprehensively evaluate various aspects of myoelectric controllability. As a result, arm position change significantly affects offline prediction accuracy, but not online control performance due to real-time feedback, thereby showing no significant correlation between offline and online performance. Donning/doffing was still problematic in online control conditions. It was further observed that no benefit was attained when using a control model trained with multiple position data in terms of arm position change, and the degree of electrode shift caused by donning/doffing was not severely associated with the degree of performance loss under practical conditions (around 1 cm electrode shift). Since this study is the first to concurrently investigate the impacts of arm position change and donning/doffing in practical myoelectric control situations, all findings of this study provide new insights into robust myoelectric control with respect to arm position change and donning/doffing.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Electronics and Information Engineering > 1. Journal Articles
Graduate School > Department of Artificial Intelligence > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE