Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Radiological, histological, and hematological evaluation of hydroxyapatite-coated resorbable magnesium alloy screws placed in rabbit tibia

Authors
Lim, Ho-KyungByun, Soo-HwanLee, Jin-YongLee, Jung-WooKim, Sae-MiLee, Sung-MiKim, Hyoun-EeLee, Jong-Ho
Issue Date
8월-2017
Publisher
WILEY
Keywords
bioresorbable screw; magnesium; magnesium alloy (WE43); biocompatibility; HA coating
Citation
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, v.105, no.6, pp.1636 - 1644
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
Volume
105
Number
6
Start Page
1636
End Page
1644
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/82727
DOI
10.1002/jbm.b.33703
ISSN
1552-4973
Abstract
Titanium (Ti) screw has excellent mechanical property, and osseointegration capacity. However, they require surgery for removal. In contrast, polymer screws are resorbable, but they have poor mechanical properties. In this research, magnesium alloy screws (WE43: Mg-Y-Nd-Zr) that have advantages of titanium and polymer were manufactured. In addition, to increase biocompatibility and control degradation rate, the Mg alloy was coated with hydroxyapatite (HA). Torsion test and corrosion test were performed in vitro. For clinical, radiological and histological evaluation, on the eight rabbits, two HA-coated screws were installed in left tibia, and two noncoated screws were installed in right tibia. Each four rabbits were sacrificed 6 and 12 weeks postoperatively. For hematological evaluation, the same type of screws were installed on both legs. Complete blood count (CBC), Mg2+ concentrate were sampled from the ear central artery on the operation day for a control point, and at 1, 2, 4, 6, 8, and 12 weeks. Mg alloy screws have no differences of biocompatibility according to the HA coating. However, resorption of screw was slower in case of the HA coating. The hematological problem related releasing of Mg was not found. The results suggest that Mg alloy screws have feasibility for clinical application. (C) 2016 Wiley Periodicals, Inc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE