A new lateral flow strip assay (LFSA) using a pair of aptamers for the detection of Vaspin

Authors
Raston, Nurul Hanun AhmadVan-Thuan NguyenGu, Man Bock
Issue Date
15-Jul-2017
Publisher
ELSEVIER ADVANCED TECHNOLOGY
Keywords
Lateral flow strip assay (LFSA); Cognate aptamer duo; Vaspin; Sandwich-type
Citation
BIOSENSORS & BIOELECTRONICS, v.93, pp.21 - 25
Indexed
SCIE
SCOPUS
Journal Title
BIOSENSORS & BIOELECTRONICS
Volume
93
Start Page
21
End Page
25
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/82822
DOI
10.1016/j.bios.2016.11.061
ISSN
0956-5663
Abstract
A new lateral flow strip assay (LFSA) using a pair of aptamers has been designed and successfully developed using a pair of aptamers-functionalized with gold nanoparticles (AuNPs). This new LFSA biosensor system utilizes a cognate aptamer duo binding to vaspin, a target protein, at the two different binding sites, and exhibited a sensitive and highly selective response to vaspin. A sandwich-type format in LFSA was developed based on biotin-labeled primary V1 aptamer immobilized on streptavidin coated membrane as a capturing probe and secondary V49 aptamer conjugated with AuNPs as a signaling probe. Using this LFSA, vaspin could be visibly observed within the detectable concentrations of vaspin up to 5 nM in both buffer and serum conditions. The sensitivity of this LFSA developed in this study was ranged from 0.137 to 25 nM in buffer and from 0.105 to 25 nM in spiked human serum, respectively. The limit of detection (LOD) of this LFSA was found to be 0.137 nM and 0.105 nM in buffer and spiked human serum condition, respectively. Therefore, this study has shown successful development of a simple yet effective LFSA for vaspin detection, and this development is not only limited to this target, but also other targets with a pair of aptamers available, without any special and laborious instrumentations. This system will be particularly useful as a screening tool for rapid on-site detection of any targets with a pair of aptamers generated.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biotechnology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Gu, Man Bock photo

Gu, Man Bock
Department of Biotechnology
Read more

Altmetrics

Total Views & Downloads

BROWSE