Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Proximal femoral osteotomy in Legg-Calve-Perthes disease using a monolateral external fixator: surgical technique, outcome, and complications

Authors
Park, Kwang-WonShah, Ishani P.Ramanathan, Ashok K.Lee, Tae-JinSong, Hae-Ryong
Issue Date
Jul-2017
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Keywords
external fixator; Legg-Calve-Perthes disease; proximal femoral osteotomy
Citation
JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, v.26, no.4, pp.329 - 335
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B
Volume
26
Number
4
Start Page
329
End Page
335
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/83013
DOI
10.1097/BPB.0000000000000399
ISSN
1060-152X
Abstract
Although external fixation methods have been described for proximal femoral osteotomy for various etiologies, none are dedicated to a single disease entity. Our study introduces a technique of proximal femoral osteotomy and fixation with a monolateral external fixator system in Legg-Calve-Perthes disease (LCPD). Twenty-three patients (19 males, four females) with LCPD underwent surgery at our institute between 2004 and 2012. Varus osteotomy (group A, 11 hips) and valgus osteotomy (group B, 12 hips) were performed and the monolateral external fixator system was used. The average age of patients at surgery was 13 years (6-23 years) and the mean follow-up duration was 21 months (12-64 months). The mean angular correction of the varus osteotomy in group A was 20 degrees (10 degrees-28 degrees) and the mean medial displacement was 21% (10-49%). The angular correction of valgus osteotomy in group B was 28 degrees (14 degrees-49 degrees) and lateral displacement was 41% (38-58%). The mean fixation time was 14 weeks (8.4-31 weeks). Complications occurred in nine hips (39.1%) and included pin-tract infections (five), hip abduction contracture (one), nonunions (two), and refracture (one). Our surgical technique provides precise correction and stable fixation with minimal intervention. Therefore, the monolateral external fixator could be considered an acceptable alternative fixation device for the correction of proximal femoral deformities in patients with LCPD. Level of evidence: Level IV, case series. Copyright (C) 2017 Wolters Kluwer Health, Inc. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE