Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis

Authors
Park, Jin-YoungBae, So-YeonLee, Jae-JunKim, Ji-HwanKim, Hae-YoungKim, Woong-Chul
Issue Date
6월-2017
Publisher
KOREAN ACAD PROSTHODONTICS
Keywords
Silicone replica technique; Three-dimensional superimposition analysis; CAD/CAM; Polyetherketoneketone; Marginal and internal gap
Citation
JOURNAL OF ADVANCED PROSTHODONTICS, v.9, no.3, pp.159 - 169
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF ADVANCED PROSTHODONTICS
Volume
9
Number
3
Start Page
159
End Page
169
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/83325
DOI
10.4047/jap.2017.9.3.159
ISSN
2005-7806
Abstract
PURPOSE. The purposes of this study were to evaluate the marginal and internal gaps, and the potential clinical applications of three different methods of dental prostheses fabrication, and to compare the prostheses prepared using the silicone replica technique (SRT) and those prepared using the three-dimensional superimposition analysis (3DSA). MATERIALS AND METHODS. Five Pekkton, lithium disilicate, and zirconia crowns were each manufactured and tested using both the SRT and the two-dimensional section of the 3DSA. The data were analyzed with the nonparametric version of a two-way analysis of variance using rank-transformed values and the Tukey's post-hoc test (a = .05). RESULTS. Significant differences were observed between the fabrication methods in the marginal gap (P < .010), deep chamfer (P < .001), axial wall (P < .001), and occlusal area (P < .001). A significant difference in the occlusal area was found between the two measurement methods (P < .030), whereas no significant differences were found in the marginal gap (P > .350), deep chamfer (P > .719), and axial wall (P > .150). As the 3DSA method is three-dimensional, it allows for the measurement of arbitrary points. CONCLUSION. All of the three fabrication methods are valid for measuring clinical objectives because they produced prostheses within the clinically acceptable range. Furthermore, a three-dimensional superimposition analysis verification method such as the silicone replica technique is also applicable in clinical settings.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hae Young photo

Kim, Hae Young
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE