Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of two-dimensional synthesized mammogram (2DSM) and conventional full-field digital mammogram (FFDM) for evaluation of breast cancer

Authors
Choi, GayoungWoo, Ok HeeShin, Hye SeonJang, SeonahCho, Kyu RanSeo, Bo Kyoung
Issue Date
5월-2017
Publisher
ELSEVIER SCIENCE INC
Citation
CLINICAL IMAGING, v.43, pp.170 - 174
Indexed
SCIE
SCOPUS
Journal Title
CLINICAL IMAGING
Volume
43
Start Page
170
End Page
174
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/83575
DOI
10.1016/j.clinimag.2017.03.004
ISSN
0899-7071
Abstract
Purpose: To compare the diagnostic efficacy of 2DSM and FFDM for evaluation of breast cancer. Materials and methods: A retrospective observer performance study was done by 3 breast radiologists. The diagnostic accuracy, image quality, and detailed lesion characterization of each 2DSM and FFDM were evaluated blindly to determine superior modality. Results: The diagnostic accuracy was not significantly different between two modalities. The image quality was superior in 2DSM (p-value 0.0362). Conclusions: 2DSM showed equivalent diagnostic accuracy and superior image quality to FFDM. Overall characterization of the lesion was better in 2DSM, and 2DSM showed superiority in evaluation of spiculated margins. (C) 2017 Elsevier Inc. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Kyu Ran photo

Cho, Kyu Ran
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE