Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Application of multiple modified fouling index (MFI) measurements at full-scale SWRO plant

Authors
Jin, YongxunLee, HyunkyungJin, Yang OhHong, Seungkwan
Issue Date
1-4월-2017
Publisher
ELSEVIER SCIENCE BV
Keywords
Membrane fouling; Modified fouling index (MD); Silt density index (SDI); Seawater RO desalination; Multiple MD measurements
Citation
DESALINATION, v.407, pp.24 - 32
Indexed
SCIE
SCOPUS
Journal Title
DESALINATION
Volume
407
Start Page
24
End Page
32
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/83797
DOI
10.1016/j.desal.2016.12.006
ISSN
0011-9164
Abstract
Recently, a modified fouling index (MFI) is published on ASTM, and thus, is expected to become a standard method for evaluating fouling potential, as a supplement to silt density index (SDI). Employing membranes with smaller pore size in MFI measurements has been continuously suggested in many previous studies. However, there was a lack of practical studies verifying the usefulness of MFI. In this study, the applicability of multiple MFIs (i.e., MFI0.45, MFI-UF100 (kDa) and MFI-UP10 (kDa)) were evaluated at a full-scale UF/RO seawater desalination plant located in the Middle East. For a year, MFIs were measured with RO feed water and the results were correlated with increments in differential pressure (DP) of RO process. Regression analysis was conducted in order to find out whether the fouling index could predict RO performance deterioration. The observed MFIs clearly showed correlation with DP variation, while SDI and water quality parameters (e.g. turbidity and UV254) exhibited relatively low accordance. Particularly, MFI-UF100 (kDa) was the most sensitive, indicating that colloidal fouling is the main cause of fouling in SWRO desalination. The regression results were reconfirmed through specific events where feed water quality was severely changed due to red tide or ship movement at intake. These events provided unconventional feed water characteristics, but similar trend was observed that MFI-UF100 (kDa) was most sensitive. The application of MFI in an actual plant provided valuable contribution for the further advancement of MFI measurements. (C) 2016 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Seung kwan photo

Hong, Seung kwan
공과대학 (건축사회환경공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE