OPTIMAL BETA-RAY SHIELDING THICKNESSES FOR DIFFERENT THERAPEUTIC RADIONUCLIDES AND SHIELDING MATERIALS
- Authors
- Cho, Yong In; Kim, Ja Mee; Kim, Jung Hoon
- Issue Date
- 4월-2017
- Publisher
- OXFORD UNIV PRESS
- Citation
- RADIATION PROTECTION DOSIMETRY, v.174, no.1, pp.13 - 20
- Indexed
- SCIE
SCOPUS
- Journal Title
- RADIATION PROTECTION DOSIMETRY
- Volume
- 174
- Number
- 1
- Start Page
- 13
- End Page
- 20
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/83960
- DOI
- 10.1093/rpd/ncw076
- ISSN
- 0144-8420
- Abstract
- To better understand the distribution of deposited energy of beta and gamma rays according to changes in shielding materials and thicknesses when radionuclides are used for therapeutic nuclear medicine, a simulation was conducted. The results showed that due to the physical characteristics of each therapeutic radionuclide, the thicknesses of shielding materials at which beta-ray shielding takes place varied. Additional analysis of the shielding of gamma ray was conducted for radionuclides that emit both beta and gamma rays simultaneously with results showing shielding effects proportional to the atomic number and density of the shielding materials. Also, analysis of bremsstrahlung emission after beta-ray interactions in the simulation revealed that the occurrence of bremsstrahlung was relatively lower than theoretically calculated and varied depending on different radionuclides.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - Graduate School of Education > Computer Science Education > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.